Kelvinator Air Conditioning

  installation instructions  9

Spanner

Torque

wrench

Piping

Taper nut

Indoor unit piping

Model 

Suction 

(mm)

Discharge 

(mm)

Maximum  Maximum 

6.4 (1/4")

15

10

6.4 (1/4")

15

10

6.4 (1/4")

20

10

6.4 (1/4")

20

10

6.4 (1/4")

16.0 (5/8")

25

10

6.4 (1/4")

16.0 (5/8")

10

6.4 (1/4")

16.0 (5/8")

25

10

6.4 (1/4")

16.0 (5/8")

25

10

6.4 (1/4")

16.0 (5/8")

25

10

Note:

 

Connect the connection pipe to indoor unit at first and then 
to outdoor unit. Handle piping bending with care. Do not 
damage the connection pipe. Ensure that the joint nut is 
tightened firmly, otherwise, it may cause leakage.

Installation of outdoor unit

Electric wiring

1   Remove the handle on the right side plate of 

outdoor unit.

2   Take off wire cord anchorage. Connect and fix power 

connection cord to the terminal board. Wiring should fit 
that of indoor unit.

3   Fix the power connection cord with wire clamps and then 

connect the corresponding connector.

4   Confirm if the wire has been fixed properly.
5  Reinstall the handle.

For 2.6kW and 3.5kW units:

Air Purging and Leakage Test

1   Connect charging hose of manifold valve to charge end 

of low pressure valve (both high/low pressure valves 
must be tightly shut).

2  Connect joint of charging hose to vacuum pump.
3  Fully open the handle of Lo manifold valve.
4   Open the vacuum pump for vacuumization. At the 

beginning, slightly loosen joint nut of low pressure valve 
to check if there is air coming inside. (If noise of vacuum 
pump has been changed, the reading of multimeter is 0) 
Then tighten the nut.

5   Keep vacuuming for more than 15mins and make sure the 

reading of multi-meter is -1.0 10

5

pa (-76cmHg).

6  Fully open high/low pressure valves.
7   Remove charging hose from charging end of low 

pressure valve.

8  Tighten lid of low pressure valve. (As shown in below)

Multimeter

-76cmHg

Lo Handle

Charging hose

Hi handle

Charging hose

Low pressure valve

Manifold

Valve

Vacu um pump

Outdoor Condensate Drainage (only for Heat pump unit)

During heating operation, the condensate and defrosting 
water should be drained out reliably through the drain hose.
Install the outdoor drain connector in a  25mm hole on the 
base plate and attach the drain hose to the connector so 
that the waste water formed in the outdoor unit can be 
drained out. The hole diameter 25mm must be plugged.
Whether to plug other holes will be determined by the 
installer according to actual conditions.

Drain-water hole

Bottom frame

Drain plug

Hose (available commercially,

inner diameter 16mm)

Drain connecter

25

length(m)

Height(m)

12.7  (1/2")

12.7  (1/2")

12.7  (1/2")

12.7  (1/2")

For 5.3kW, 6.2kW, 7.0kW and 8.8kW units:

KSE26CRC

KSE26HRC

KSE35CRC

KSE35HRC

KSE53HRC

KSE62HRC

KSE70CRC

KSE70HRC

6.4 (1/4")

16.0 (5/8")

25

10

KSE88HRC

KSE88CRC

Handle

yellow-

black

blue

2

N(1)

3

indoor unit connection

green

yellow-

white

black

blue

brown

blue

2

N(1)

3 4 5

indoor unit connection

green

2.6kW,3.5kW  Cool only type

2.6kW,3.5kW  Cool and Heat type

violet

orange

7.0 kW,8.8 kW Cool only type

6.2 kW,7.0 kW,8.8 kW Cool and Heat type

5.3kW  Cool and Heat type

yellow-

brown

black

blue

white

2

N(1)

3 6

indoor unit connection

green

Handle

yellow-

brown

black

blue

2

N(1)

3

indoor unit connection

green

1

3

2

X1

X2

white

Содержание KSE26CRC

Страница 1: ...Installation Manual Refrigerant R410A KSE26CRC KSE26HRC KSE35CRC KSE35HRC KSE53HRC KSE62HRC KSE88HRC KSE70CRC KSE70HRC KSE88CRC Fixed Speed Split Room Air Conditioner ...

Страница 2: ...e contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact an authorised installer for installation of this unit Contact an authorised service technician for repair or main...

Страница 3: ...of the following If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard warning Before obtaining access to terminals all supply circuits must be disconnected Please read this installation manual and the user manual before installation and carefully store in a handy place for later reference Inside you will f...

Страница 4: ...taminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation Site of Indoor Unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be blown through the whole room 2 Select a site where the condensing water can be easily drained out and where it is easily connected for the ou...

Страница 5: ...re not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided space necessary for properinstallation of the unit include the minimumpermissible distances to adjacent parts Space to the wall 200cm Above 30cm Above Space to the obstruction Air outlet side e v o b 50cm A Space to the wall Air inlet side 30cm Above 50cm Above the ...

Страница 6: ...ard slightly without distortion bulge or fluctuation Do not put the outlet in the water Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally As the water tray s outlet for the indoor unit is two way type during installation the indoor unit should slightly slant to water tray s outlet for smooth drainage of condenser water 2 Fix the mounti...

Страница 7: ...e should be 2m or more above the floor Right Fig 2 Fig 1 Tailing 1 Tailing 2 Finally wrap it with tape Gas side piping insulation Water drainage pipe Liquid side Piping insulation Gas side pipe External connection electric wire Liquid side piping Fig 3 Mounting plate Fixing hook Installation of Connection Pipe Align the center of the piping flare with the related valve Screw in the flare nut by ha...

Страница 8: ... refrigerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable 1 Use the piping kit accessory if applicable or pipes purchased locally 2 Measure the distance between the indoor and the outdoor unit 3 Cut the pipes a little longer than the measured distance 4 Cut the cable 1 5m longer ...

Страница 9: ...0 Then tighten the nut 5 Keep vacuuming for more than 15mins and make sure the reading of multi meter is 1 0 105 pa 76cmHg 6 Fully open high low pressure valves 7 Remove charging hose from charging end of low pressure valve 8 Tighten lid of low pressure valve As shown in below Multimeter 76cmHg Lo Handle Charging hose Hi handle Charging hose Low pressure valve Manifold Valve Vacuum pump Outdoor Co...

Страница 10: ...pacity is not accurate Operation Test 1 Before Operation Test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation Test Method a Switch on power and press ON OFF button on the remo...

Страница 11: ...ranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect powe...

Страница 12: ...or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au 2011 Electrolux Home Products Pty Ltd ABN 51 004 762 341 66129909283 ...

Отзывы: