2 Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
Ø
55/
Indoor
Outdoor
Wall pipe
Seal pad
Installation of Drain Hose
1 Connect the drain hose to the outlet pipe of the
indoor unit. Bind the joint with rubber belt.
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
rubber belt
2 Put the drain hose into insulating tube.
insulating tube
drain hose
outlet pipe of
indoor unit
rubber belt
3 Wrap the insulating tube with wide rubber belt to
prevent the shift of insulating tube. Slant the drain
hose downward slightly for smooth drainage of
condensing water.
outlet pipe of
indoor unit
insulating tube
connected
rubber belt
Note:
The insulating tube should be connected reliably with the
sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet in the water.
Installation of indoor unit
Installation of Mounting Plate
1 The mounting plate should be installed horizontally.
As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly
slant to water tray's outlet for smooth drainage of
condenser water.
2 Fix the mounting plate on the wall with screws.
3 Be sure that the mounting plate has been fixed firmly
enough to withstand about 60kg. Meanwhile, the weight
should be evenly shared by every screw.
Note: All dimensions are in mm.
Ø55
Ø55
34.5
316
160
35
80
Above 150mm
from the ceiling
159
1048
346
70
70
70
39
83
90
55
130
81
90
55
94
166
281
575
158
685
205
70
3.5kW UNIT:
Drill Piping Hole
1 Slant the piping hole on the wall slightly downward to
the outdoor side.
Piping hole
Units
( 55)
6 Installation instructions
Kelvinator Air Conditioning
bulge
distortion
Flooded
( 70)
2.6 kW, 3.5 kW
Ø
7 0
5.3kW UNIT:
5.3kW,
2.6kW ,
6.2 kW, 7.0 kW and 8.8 kW UNITS:
6.2 kW, 7.0 kW and 8.8 kW