5.4 Connecting Lamp Head and Controller
Use the 4-pin XLR head cable to connect the Lamp Head Fixture with the Controller.
See illustration below.
5.5
Powering the Epos 300
AC Power
1. Connect the 4-pin XLR cable to the power supply and the Epos 300.
2. Connect the AC cable to the power supply and a power outlet.
Battery Power
1. Connect the 4-pin XLR cable to the power supply and the Epos 300 controller.
2. Slide a battery into the power supply’s battery plate until it locks into place.
To remove the battery, press the battery release, and slide it off the plate.
Important! If the power supply is connected to both a 26 V battery and an AC power source, the
power supply will draw from the 26 V battery instead of the AC power. To preserve battery life, connect a 26 V
battery to the power supply only when you intend to use it.