5. Maintenance and care
KENOVA set line V9xx(-S)
© Kelch GmbH 2014
Kelch GmbH · Werkstraße 30 · D-71384 Weinstadt-Endersbach · Tel. (+49)7151 20522 0 · Fax (+49)7151 20522 11 · [email protected]
Page 31
5.4.1 Servicing Schedule
Copy the following servicing schedule and use it as a check list. At the end of the work,
date and sign the filled-in page and save as a work report.
Servicing Interval
Result
Maintenance Work
Daily Weekly Monthly Yearly Every 2 years OK not OK
Check protective cover
X
Check guide cover bands for damage
X
Check the maintenance unit setting
(5 bar)
X
Inspect air lines and valves for seal
tightness
X
Clean or replace air filter (PC)
X
Check the ropes, pulleys and axles of
the counterweight for damage.
Replace damaged components
X
Check the run-out of the adapter
X
Check the parallelism of the tapered
holder to the longitudinal guide.
X
Check the focus adjustment of the
camera
X
Check the setting of the light source;
readjust if necessary.
X
Check the rope of the counterweight.
Check the shaft and pulley for wear.
Replace parts if worn
X
Inspect induction coil for damage
X
Lack of, or poorly performed, maintenance of the
system can have the following effect:
We recommend that maintenance be carried out by
specialists from Kelch GmbH
- Reduced
operational
reliability
-
Unnecessary standstills
Tel: +49 7151-20522-640
-
Avoidable repair costs
Fax: +49 7151-20522-11
-
Shortened service life
Date:
Signature:
Содержание KENOVA set line V9 S Series
Страница 2: ......