KPCI-3160 User’s Manual
Troubleshooting
5-21
Figure 5-9
Configuring channel 0 for output bit pattern B
17. In the
Digital Output Panel
under
Output
Bits
, set the bits of channel 0 for bit pattern B as
shown in
Figure 5-9
.
18. In the
Digital Input Panel
under
Channels
, click on channel
1
as shown in
Figure 5-10
.
Figure 5-10
Proper response of channel 1 bits when channel 0 output bits
are set to bit pattern B
19. In the
Digital Input Panel
under
Input bits
observe the bit pattern.
Figure 5-10
shows the
proper response.
•
If the observed input bit patterns are not the same as shown in
Figure 5-10
, the digital
I/O is not functioning properly. Stop here, and return to the problem isolation step that
asked you to perform the General-purpose digital I/O hardware test.
•
If the input bit patterns are the same as shown in
Figure 5-10
, continue with step 20.
20. In the
Digital Input Panel
under
Channels
, click on channel
2
as shown in
Figure 5-11
.
KEITHLEY
Digital Output Panel
Channels
0
1
2
3
4
5
6
7
Output Bits
8
9
10
11
12
13
14
15
AA
7
6
5
4
3
2
1
0
KEITHLEY
Digital Input Panel
Channels
0
1
2
3
4
5
6
7
Input Bits
8
9
10
11
12
13
14
15
AA
7
6
5
4
3
2
1
0
•
•
•
•
•
•
•
•
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание KPCI-3160
Страница 12: ...1 Overview Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 18: ...3 Installation Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 40: ...5 Troubleshooting Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 68: ...A Specifications Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 81: ...C Glossary Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...