Safety

Do not touch any object that could provide a current path to the common side of the circuit under 

test or power line (earth) ground. Always make measurements with dry hands while standing on 

a dry, insulated surface capable of withstanding the voltage being measured.
For safety, instruments and accessories must be used in accordance with the operating 

instructions. If the instruments or accessories are used in a manner not speci

 ed in the 

operating instructions, the protection provided by the equipment may be impaired. 
Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal 

levels are de

 ned in the speci

 cations and operating information and shown on the instrument 

panels, test 

 xture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued 

protection against 

 re hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as 

protective earth (safety ground) connections. 
If you are using a test 

 xture, keep the lid closed while power is applied to the device under test. 

Safe operation requires the use of a lid interlock.
If a        screw is present, connect it to protective earth (safety ground) using the wire 

recommended in the user documentation.

The         symbol on an instrument means warning, risk of electric shock. Use standard safety 

precautions to avoid personal contact with these voltages.

The       symbol indicates a connection terminal to the equipment frame.

The         symbol on an instrument means caution, risk of hazard. The user must refer to the 

operating instructions located in the user documentation in all cases where the symbol is 

marked on the instrument.

The         symbol on an instrument shows that the surface may be hot. Avoid personal contact to 

prevent burns.

If this         symbol is on a product, it indicates that mercury is present in the display lamp. Please 

note that the lamp must be properly disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains hazards that might result 

in personal injury or death. Always read the associated information very carefully before 

performing the indicated procedure.
The 

CAUTION

 heading in the user documentation explains hazards that could damage the 

instrument. Such damage may invalidate the warranty.
The 

CAUTION

 heading with the        symbol in the user documentation explains hazards that 

could result in moderate or minor injury or damage the instrument. Always read the associated 

information very carefully before performing the indicated procedure. Damage to the instrument 

may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 
To maintain protection from electric shock and 

 re, replacement components in mains circuits 

— including the power transformer, test leads, and input jacks — must be purchased from 

Keithley. Standard fuses with applicable national safety approvals may be used if the rating and 

type are the same. The detachable mains power cord provided with the instrument may only be 

replaced with a similarly rated power cord. Other components that are not safety-related may 

be purchased from other suppliers as long as they are equivalent to the original component 

(note that selected parts should be purchased only through Keithley to maintain accuracy 

and functionality of the product). If you are unsure about the applicability of a replacement 

component, call a Keithley o

  ce for information. 

Unless otherwise noted in product-speci

 c literature, Keithley instruments are designed to 

operate indoors only, in the following environment: Altitude at or below 2,000 m (6,562 ft); 

temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 
To clean an instrument, use a cloth dampened with deionized water or mild, water-based 

cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument 

or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 

no case or chassis (e.g., a data acquisition board for installation into a computer) should never 

require cleaning if handled according to instructions. If the board becomes contaminated and 

operation is a

 ected, the board should be returned to the factory for proper cleaning/servicing. 

Safety precaution revision as of June 2017.

Содержание DMM6500

Страница 1: ...Model DMM6500 Quick Start Guide...

Страница 2: ...r high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or highe...

Страница 3: ...the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that coulddamage the instrument Such damage may inva...

Страница 4: ...Hz to 60 Hz and 400 Hz the line frequency voltage is automatically sensed at power up Maximum VA 50 VA Operating altitude Maximum 2000 m 6562 ft above sea level Operating temperature 0 C to 50 C 80 re...

Страница 5: ...action enabling users to gain deeper insight into their measurements The DMM6500 provides superior measurement accuracy and the speed necessary for a broad range of applications from system applicatio...

Страница 6: ...the instrument for any obvious signs of physical damage Report any damage to the shipping agent immediately 1 2 3 4 You should have received the DMM6500 with 1 USB Type B cable 2 Crossover Cable for...

Страница 7: ...use orientation 1 Make sure the POWER is off 2 Remove all test leads connected to the instrument 3 Remove the power cord 4 Squeeze the tabs on the fuse case and remove the fuse case from the power mod...

Страница 8: ...ifications of all instruments in the system The overall allowed signal levels may be constrained by the lowest rated instrument in the system For example if you are using a 500 V power supply with a 3...

Страница 9: ...ide training to all users of the system so they understand all potential hazards and know how to protect themselves from injury During power up in many systems the outputs may be in an unknown state u...

Страница 10: ...quency of 50 Hz 60 Hz or 400 Hz It automatically senses line frequency Make sure the operating voltage in your area is compatible You must turn on the DMM6500 and allow it to warm up for at least 30 m...

Страница 11: ...ER switch for two seconds The indicator next to the POWER switch shows amber in the off state and green in the on state when connected to the power source The instrument displays a status bar as the i...

Страница 12: ...2 DIGIT MULTIMETER Sense HI and LO terminals Input HI and LO terminals Selects highlighted choice Returns to previous screen Selects measurement function AMPS 3A 250V Activates front or rear terminal...

Страница 13: ...Explore AMPS 10A 250V AMPS 3A 250V LO terminal HI terminal Input fuse Scanner card slot Ethernet port Trigger terminals USB Type B port Optional KTTI interface card slot Power module Fuse module...

Страница 14: ...nder test DUT that is in contact with the conductors It is good practice to disconnect DUTs from the instrument before powering the instrument Safe installation requires proper shields barriers and gr...

Страница 15: ...provide a quick way to verify that the instrument is operating correctly To verify measurement operation 1 Turn the instrument on 2 On the front panel press the HOME key 3 On the Functions swipe scree...

Страница 16: ...r Card 2001 TCSCAN 10 channel Thermocouple Scanner Card Is there any software to help me get started Yes KickStart and TestScript Builder can help you get started with the DMM6500 KickStart is a softw...

Страница 17: ...strument front panel press the MENU key 8 Under System select Info Manage 9 Choose an upgrade option To upgrade to a newer version of firmware select Upgrade to New To return to a previous version of...

Страница 18: ...nds that can be executed from a stand alone instrument You can use TSP to send individual commands or use it to combine commands into scripts SCPI2000 An instrument specific language that allows you t...

Страница 19: ...of the instrument You can save the settings in the instrument as a script using the front panel menus or from a remote interface After they are saved you can recall the script or copy it to a USB fla...

Страница 20: ...sume you have the measure function set to current and you set a value for display digits When you change the measure function to voltage the display digits value changes to the value that was last set...

Страница 21: ...for support and additional information about the instrument From the website you can access The Low Level Measurements Handbook Precision DC Current Voltage and Resistance Measurements Switching Handb...

Страница 22: ...35 Philippines 1 800 1601 0077 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 565 1455 Russia CIS 7 495 6647564 Singapore 800 6011 473 South Africa 41 52 675 3777 Spain 00800 2255 4...

Отзывы: