For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the 
circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: 
connecting or disconnecting cables or jumpers, installing or removing switching cards, or making internal changes, 
such as installing or removing jumpers.
Do not touch any object that could provide a current path to the common side of the circuit under test or power line 
(earth) ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of 
withstanding the voltage being measured.

The instrument and accessories must be used in accordance with specifications and operating instructions, or the 
safety of the equipment may be impaired.
Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and 
operating information, and as shown on the instrument or test fixture panels, or switching card.
When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard.

Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground 
connections.
If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation 
requires the use of a lid interlock.

If a 

 screw is present, connect it to safety earth ground using the wire recommended in the user documentation.

The 

 symbol on an instrument indicates that the user should refer to the operating instructions located in the 

documentation.

The 

symbol on an instrument shows that it can source or measure 1000 volts or more, including the combined 

effect of normal and common mode voltages. Use standard safety precautions to avoid personal contact with these 
voltages.

The 

 symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns.

The 

symbol indicates a connection terminal to the equipment frame.

If this 

 symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp 

must be properly disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains dangers that might result in personal injury or death. 

Always read the associated information very carefully before performing the indicated procedure.
The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such 

damage may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans.

Before performing any maintenance, disconnect the line cord and all test cables.
To maintain protection from electric shock and fire, replacement components in mains circuits - including the power 
transformer, test leads, and input jacks - must be purchased from Keithley Instruments. Standard fuses with 
applicable national safety approvals may be used if the rating and type are the same. Other components that are 
not safety-related may be purchased from other suppliers as long as they are equivalent to the original component 
(note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and 
functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley 
Instruments office for information.
To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do 
not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist 
of a circuit board with no case or chassis (e.g., data acquisition board for installation into a computer) should never 
require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, 
the board should be returned to the factory for proper cleaning/servicing.

!

Содержание 2701

Страница 1: ...1 904 01D A Greater Measure of Confidence www tek com keithley Model 2701 Ethernet Based DMM Data Acquisition System Instrument Networking Instruction Manual 2701 904 01 Rev D February 2016 P2701 904...

Страница 2: ...Model 2701 Instrument Networking Instruction Manual 2016 Keithley Instruments All rights reserved Cleveland Ohio U S A Document Number 2701 904 01 Rev D February 2016...

Страница 3: ...tional Electrotechnical Commission IEC Standard IEC 60664 Most measurement control and data I O signals are Measurement Category I and must not be directly connected to mains voltage or to voltage sou...

Страница 4: ...instrument shows that the surface may be hot Avoid personal contact to prevent burns The symbol indicates a connection terminal to the equipment frame If this symbol is on a product it indicates that...

Страница 5: ...6 Procedure 2 6 Corporate network connection 2 8 3 ConfiguringTCP IPaddresses Communication protocol 3 2 IS IT department 3 2 Direct connection isolated network 3 4 Address restrictions 3 4 Selecting...

Страница 6: ...tart up software package 4 4 KE2700 VISA Based IVI Instrument Driver 4 6 Additional software applications 4 8 ExceLINX 1A 4 8 TestPoint Application Development Package 4 9 Provided software and driver...

Страница 7: ...gure 3 7 Windows XP network configuration window 3 14 4 SoftwareandDrivers Figure 4 1 Software overview 4 2 Figure 4 2 TestPoint runtime start up software 4 4 Figure 4 3 ExceLINX 1A 4 8 Figure 4 4 Kei...

Страница 8: ...1 Introduction...

Страница 9: ...mation view and edit the Instrument s networking configuration take and display simple readings and send the instrument SCPI commands and display the results The 2701 s IP address as well as Subnet ma...

Страница 10: ...et interface control The Model 2701 s adapter supports 10BaseT and 100BaseTX Fast Ethernet Through design the Model 2701 integrates easily with fast Ethernet hubs and switches NOTE To operate at 10 Mb...

Страница 11: ...r size connectors for easier mistake free wiring Built in relay cycle counters on each module for ease of maintenance A variety of measurement and control modules makes it simple to mix match and chan...

Страница 12: ...nnector Figure 1 1 Refer to Table 1 1 for a description of LED status descriptions Table 1 1 LED status descriptions LED State Ethernet status Link Act Off Network is NOT connected Link Act On Network...

Страница 13: ...2 NetworkConnection...

Страница 14: ...f cable is used Information on four connection schemes is detailed in this section Direct connection PC to Model 2701 through a cross over cable provided Hub connection PC to one or more Model 2701s D...

Страница 15: ...dresses is required for the Model 2701 and the network interface card Figure 2 1 PC to Single Model 2701 Procedure NOTE A direct connection requires use of a cross over cable not the straight thru cab...

Страница 16: ...the Model 2701 will need to be set manually see Section 3 NOTE Different available IP addresses are required for each Model 2701 and the network interface card connected to the Model 2701 network Fig...

Страница 17: ...a CAT 5 Cable to network interface card installed in PC refer to the cards instructions for procedure 2 Connect other end of the CAT 5 Cable to an available RJ 45 connector in hub Do not connect to u...

Страница 18: ...h as for email or intranet applications This scheme maximizes the performance of the network connections to the instruments by isolating corporate network traffic from the 2701 and the PC i e when the...

Страница 19: ...e Card Properly installed in PC Existing Existing network cabling Maintains current network functions 2 CAT 5 straight thru cable Add one additional cable for each additional Model 2701 connected thro...

Страница 20: ...work settings for the Model 2701 including IP address subnet and gateway Failure to use settings provided by the sites Network Administrator could result in failures at other locations on the corporat...

Страница 21: ...3 ConfiguringTCP IPaddresses...

Страница 22: ...the Network Administrator before attempting to connect instrumentation to the network IS ITdepartment The Model 2701 supports DCHP If a DHCP server is present on the network it will automatically prov...

Страница 23: ...o use DHCP over the Ethernet use the internal web page refer to Check or set TCP IP address over Ethernet on page 3 8 Table 3 1 IT IS department quick reference guide Network resource Action Descripti...

Страница 24: ...includes each 2701 and each network interface card connected to the instruments network The following IP addresses are reserved do not assign them to any device either interface card or Model 2701 Do...

Страница 25: ...selected select the First Byte for the class from Table 3 2 NOTE Make sure to not use any restricted numbers as the First Byte number See Address restrictions on page 3 4 NOTE The first byte is the le...

Страница 26: ...ddress selected does not matter it can be set to 0 0 0 0 Figure 3 1 IP address byte location sample Subnet mask 255 255 255 0 Subnet mask 255 255 255 0 Network ID Must be the same for all nodes on the...

Страница 27: ...hernet VIEW is displayed 3 Press Enter to select VIEW 4 Use the and range keys to scroll between ADDRESS SUBNET GATEWAY MAC read only cannot change 5 Press enter to view the desired setting SettheIPad...

Страница 28: ...page using IE 5 0 or greater see Figure 3 2 Use the IP address of 2701 as the web page address NOTE Netscape Navigator is not supported Also use of a Macintosh computer is not sup ported The PC must b...

Страница 29: ...Model 2701 Instrument Networking Instruction Manual Configuring TCP IP addresses 3 9 Figure 3 2 Internal web page...

Страница 30: ...s make up the Net work ID For example in Figure 3 3 the Network ID is 192 168 0 Figure 3 3 Command window w ipconfig To configure a network interface card the TCP IP protocol must also be installed an...

Страница 31: ...rd s If there is no TCP IP protocol listed you must add one This is done by clicking the Add button Then click on Protocol select Microsoft and click TCP IP 5 After selecting the TCP IP protocol click...

Страница 32: ...ter TCP IP protocol installation click on Properties On the IP Address tab select the proper adapter NIC then select the method of obtaining your IP address For an iso lated network click on Specify A...

Страница 33: ...listed and selected If not click on Install then select Protocol and click Add 6 Select the TCP IP protocol then click Install 7 Go back to the General tab window select the TCP IP protocol and click...

Страница 34: ...protocol listed and selected If not click on Install then select Protocol and click Add 6 Select the TCP IP protocol then click Install 7 Go back to the General tab window select the TCP IP protocol a...

Страница 35: ...t be used to connect to hub straight through cables should not be used to connect directly to the Model 2701 with out a hub IP address conflict Make sure each node interface card and 2701 has a unique...

Страница 36: ...rporate LAN IP addresses that are assigned by the IS IT department may take a period of time before they are active Check with them as to when the IP address will become active Network IDs may be diff...

Страница 37: ...4 SoftwareandDrivers...

Страница 38: ...of application solutions The individual components are described later in this section Installation and configuration details are provided at the end of this section Figure 4 1 Software overview TestP...

Страница 39: ...b page see Figure 3 2 The built in web diagnostic interface allows for easy communication and debugging without the need to install external software This interface makes it easy to read and set netwo...

Страница 40: ...A few clicks of the mouse are all it takes to confirm that the system s hardware wiring communications and software drivers are installed and operating correctly Data from multiple channels of a sing...

Страница 41: ...Supported Plug in Switch Modules 7700 7702 7708 Not supported Digital I O Analog outputs on off control of switches custom control sequences math filtering limits and scaling System Requirements Penti...

Страница 42: ...ver features BenefitsofVISA VirtualInstrument Software Architecture Provides transparent software compatibility with Ethernet GPIB and RS 232 No soft ware changes are required when changing communicat...

Страница 43: ...Supported Plug in Switch Modules All modules supported by the instrument System Requirements Pentium class PC with Windows 98 SE Windows NT4 SR6 Windows ME Windows 2000 or Windows XP Professional Mod...

Страница 44: ...iminate time consuming and error prone programming Acquire data into a spreadsheet on the fly during a scan or transfer data into a spreadsheet after a scan is completed A few mouse clicks are all it...

Страница 45: ...d control Database toolkit provides access to popular database packages like Access SQL Oracle and others Statistical process control SPC toolkit adds charts statistics and analysis capabilities Table...

Страница 46: ...irectory of the CD Follow the on screen prompts to install both the start up software TestPoint runtime and the KE2700 instrument driver Although the software provided on the CD is the current version...

Страница 47: ...ard open the Keithley Configuration Panel From the Start Menu select Programs Keithley Instruments Keithley Configuration Panel 2 Follow the wizard s prompts Figure 4 4 through Figure 4 10 contains an...

Страница 48: ...4 12 Software and Drivers Model 2701 Instrument Networking Instruction Manual Figure 4 5 Select operation window Figure 4 6 Select communication bus type window...

Страница 49: ...Model 2701 Instrument Networking Instruction Manual Software and Drivers 4 13 Figure 4 7 Select IP address window Figure 4 8 Select instrument driver window...

Страница 50: ...re and Drivers Model 2701 Instrument Networking Instruction Manual Figure 4 9 Assign instrument name window NOTE Change the name to anything that will help you identify your instrument Figure 4 10 Sum...

Страница 51: ...ettings unless you are completely familiar with their purpose and effects One advanced setting that many advanced users may wish to adjust is the QueryInstrStatus attribute setting By default the KE27...

Страница 52: ...d and use the configuration panel as shown Figure 4 11 3 Select the instrument whose configuration setting you wish to modify 4 Then double click on the QueryInstrStatus attribute in the right hand pa...

Страница 53: ...Model 2701 Instrument Networking Instruction Manual Software and Drivers 4 17 Figure 4 12 Attribute setting Figure 4 13 Advanced configuration window view changed attribute...

Страница 54: ...A Cablediagrams...

Страница 55: ...configuration is required Straightthroughcables Standard Ethernet straight through cables are required when connecting the device to a stan dard network hub or switch NOTE Straight through cables are...

Страница 56: ...over cables are typically labeled cross over or XO at one or both ends Figure A 2 Cross over cables 1 8 1 8 1 Orange White 2 Orange 3 Green White 4 Blue not used 5 Blue White not used 6 Green 7 Brown...

Страница 57: ...ery The DNS provides the protocol that allows clients and servers to communicate with each other Dynamic Host Configuration Protocol DHCP A feature of Windows NT server that automatically assigns IP a...

Страница 58: ...on of nodes and cable links in a LAN local area network NIC Network interface card is a computer card that is installed in a computer that allows the computer to communicate with a network Packet A ch...

Страница 59: ...g requests for information framed conforming to HTTP HyperText Transfer Protocol The web server processes the requests and provides the requested information Winsock An open standard specifying how a...

Страница 60: ...k 3 4 DNS 3 3 3 11 3 12 Window 98 ME 3 11 Windows 2000 3 13 Windows NT4 3 12 Windows XP 3 14 drivers 4 10 Dual interface card connection 2 6 E Ethernet Cables A 2 Ethernet interface 1 3 ExceLINX 1A 4...

Страница 61: ...operty of Keithley Instruments All other trademarks and trade names are the property of their respective companies Keithley Instruments Corporate Headquarters 28775 Aurora Road Cleveland Ohio 44139 44...

Отзывы: