Example of setting up CH1/CH2 tracking mode:
1. Press the
CH1
key.
2. Press the
V-Set
key and enter the voltage value for
channel 1. For example, set the voltage of channel 1
to 3 V.
3. Press the
Enter
key.
4. Press the
CH2
key.
5. Press the
V-Set
key and enter the voltage that sets the
ratio you want maintain for channel 2. For example, set
the voltage of channel 2 to 6 V. The ratio is 2.
6. Press the
Enter
key.
7. Press the
Menu
key.
8. Use the down arrow key to go to
Track
, and then
press the
Enter
key.
9. Press the down arrow key to select
Track CH1/CH2
and then press the
Enter
key to turn on tracking.
10. Verify that
T
is displayed between the voltage readings of
channel 1 and channel 2 on the display. This
indicates that the power supply is in tracking mode.
To disable the tracking function:
1. Press the
Menu
key.
2. Use the arrow keys to select
Track
.
3. Press the
Enter
key.
4. Use the arrow keys to select
Track Off (default)
.
5. Press the
Enter
key.
NOTE
If the voltage or current is set to 0, voltage or current tracking
is ignored.
If tracking is enabled and CH1 and CH2 timers are both set,
the timer uses the smaller set value.