manualshive.com logo in svg
background image

1021 

|

 1022 SMALL AIR COMPRESSOR

07

1. 

Power ON: 

Plug the power cord to the appropriate power 

supply to power ON the air compressor.
The air compressor is not equipped with a power ON/OFF 
switch. Power is controlled by the power cord plugged at 
the electrical outlet. 
The air compressor software is factory preset to shut off 

the motor at 118–120 psig (8.14–8.27 bar) and to re-start at 

97 

±

5 psig (6.69 

±

0.34 bar).

2. 

Power OFF: 

The air compressor is designed to remain in 

the power ON condition. There is no need to power OFF 
the air compressor, other than for care and maintenance 
purposes (see the Care and Maintenance section below 

for complete instructions).

Clean the air compressor exterior with a soft brush or wipe 
with a moistened cloth using only water and mild soap. 
Wipe dry the air compressor.
Do not use cleaning solvents as they can be toxic and 

flammable.

Always keep parts clean from dirt and dust for optimal 
equipment performance.

Make sure all connections are tight. Do not overtighten. Any 
leaks at air line connections will diminish air compressor 
performance.
To test for leaks, spray a small amount of soapy water on the 
area suspected of leaking. If the soap bubbles, try tightening 
the connection or replace the broken part. Do not install 
used compression nuts. Do not use the air compressor until all 

repairs have been completed and tested by a Keiser-certified 

technician.

DAILY OPERATION

CARE AND MAINTENANCE

CAUTION

HOT SURFACE

Before cleaning the air compressor:
1.  Disconnect the power cord from the power supply.
2.  Allow the air compressor to cool down.

CLEANING

Lubrication: 

The motor is oil-less and requires no lubrication. 

Air Lines:

 Check for damaged, torn, or otherwise broken Air 

Lines. If any damage is found, do not use until all repairs have 

been completed and tested by a Keiser-certified technician.

Inspect: 

Periodically inspect the air compressor for damaged, 

worn, or broken parts; check for normal operating sounds and 
any error codes. Make note of any error code and contact 
Keiser Customer Support for service and corrective action.
All repairs and maintenance shall only be performed by Keiser-

certified technicians. 

Do not open any parts or components 

of the air compressor or attempt to resolve any issue on 
your own. Only use replacement parts recommended by Keiser 
Corporation.

MAINTENANCE

TEST FOR LEAKS

1.  Disconnect the power cord to power OFF, and wrap the 

power cord around the air compressor handle to reduce 
the risk of damage.

2. 

Disconnect all 1/4-inch quick-disconnect (QD) or 3/8-inch 

air line from the air compressor.

3.  Slowly purge the air tanks to release all air pressure.
4.  Clean the air compressor to remove all dirt and dust.
5.  Place a cover over the air compressor to protect the unit 

from dust and moisture.

6.  Do not stack or store any items on top of or around the 

air compressor.

7.  Store indoors.

STORAGE

Содержание 1021

Страница 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Страница 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Страница 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Страница 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Страница 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Страница 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Страница 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Страница 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Страница 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Страница 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Страница 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Страница 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...

Отзывы: