background image

PAGE

 

1

 

 

Inflatable Boat Electric Air Pump Manual 

 

 

 

Congratulations 

on your purchase of the 12V Electric Air Pump. Please take a few moments to read these 

instructions to become familiar with its operation. Be certain to read the Safety Instructions before using the air 
pump. Also keep the manual with your air pump for further instruction or warranty service. 

 

Pump - 80DB 

Pump - 80D / GP120

 

 

 

If you are not happy with your purchase, please contact seller immediately and you can send back to pump to our service 

depot. Address is 120-11791 Machrina Way, Richmond, BC, Canada V7A 4V3   [email protected] 

 
 

Important Safety Instructions 

 
 

To guard against injury, basic safety precautions should be observed: 

 

 

To avoid possible electrical shock or fire, special care should be taken when using near the water or metal. 
Don't use the pump close to your Fuel Tank or An Open Flame. 

 

Please make sure the pump with correct pressure setting for your chamber before pumping at every time. 
This Pump can hold the last pressure setting after disconnect the power. Factory default setting is 25Kpa 
(3.6 PSI) when the pump is new. 

 

Make sure the connection is correct when hook up to the battery. 

 

Keep the pump away from Children. Store the pump in a dry & cool area away from water, sun and heat. 

Summary of Contents for 80D/GP120

Page 1: ... Machrina Way Richmond BC Canada V7A 4V3 support seamaxmarine com Important Safety Instructions To guard against injury basic safety precautions should be observed To avoid possible electrical shock or fire special care should be taken when using near the water or metal Don t use the pump close to your Fuel Tank or An Open Flame Please make sure the pump with correct pressure setting for your cham...

Page 2: ...g time is limited to 15 minutes Long periods of use can cause overheating and damage the inflator Smaller valve fittings can limit the airflow speed the pump could be easier to get overheat Your attention is very important and the pump continued working time must be reduced Low quality power source will slow down a lot pump running at high pressure 2nd stage it can cause the pump over heat quickly...

Page 3: ...ing The Boston type Leafield C7 air valve use a built in rubber diaphragm or diaphragm spring they will cause excessive back pressure When inflating chambers with this style of valve you must monitor the pump closely This style of valve causes the pump to overheat prematurely because of the back pressure caused by the valve diaphragm This back pressure will give the pump s sensor a false reading a...

Page 4: ...KPa and PSI 10KPa 100mbr 1 45 PSI Factory default working pressure is set as 25KPa 3 6 PSI This pressure is suitable for most inflatable boats Min set pressure is 1 PSI 8Kpa if you only need lower pressure than 1 PSI you can keep monitoring the screen pressure reading and stop the pump manually Press the POWER button to start During inflation the left hand side of LCD screen should show the pressu...

Page 5: ...ger The type of this battery is 12V gel battery lead acid type battery capacity 7AH The battery will have up to 500 Cycles up to 8 years battery life time if you can follow this maintenance manual Always keep the pump battery 80DB full charged before putting at storage or after every use The charger is 110 240V travel type with double charging procedures When you plug in the charge and connect wit...

Page 6: ...ir hose 2 Air valve adaptors 3 Lead Acid battery pack 4 110 240 Lead Acid Battery AC Charger 14V 5 Power cord 80D 4 Carrying bag 80D or 80DB 5 Turbine fan motor unit 6 Cylinder unit for 2nd stage 7 motor for cylinder 8 Electric sensor for air pressure 9 LCD display control board 10 Power relay control board 11 Other Parts 2 Years Limited Warranty For recreational using the electrical control board...

Page 7: ...LTAGE DC 11 0V MAX OPERATION VOLTAGE DC 14V Shipping weight 3 0KG 6 8Lbs Packing 22x22x27cm 8x8x11 inches Model SMX 80BD Package Battery Built in Model Additional Features Built in 7AH Lead Acid Gel Battery 110 240V Travel Charger Max Charger Current DC 14V 1 A Max charging time 72 Hours including Battery Recovery Step Shipping weight 6 2KG 13 6Lbs Packing 43x45x37cm 8x8x14 inches Model SMX GP120 ...

Page 8: ...dos etapas y el sonido de cada etapa es diferente La segunda etapa producirá ruido ruidoso ya que los cilindros duales bombean Antes de conectar la bomba de la batería asegúrese de que el voltaje de la batería es de 12V y la carga máxima de la fuente de alimentación puede soportar 30A de corriente Por favor devuelva la unidad al fabricante o al lugar de compra para servicio o reemplazo Las reparac...

Page 9: ... de válvula debe monitorear la bomba de cerca Este tipo de válvula hace que la bomba se sobrecaliente prematuramente debido a la contrapresión causada por el diafragma de la válvula Esta contrapresión dará una falsa lectura al sensor de la bomba y hará que la segunda etapa comience temprano Esto hará que la bomba funcione más y más Nuestros adaptadores de válvula universal pueden encajar casi todo...

Page 10: ...flado La segunda etapa nunca se iniciará ya que la función de control de presión no funciona Cuando tenga la mayor parte del aire fuera de la cámara apague la bomba y desconecte la manguera de esa cámara Debe apagar la bomba manualmente ya que no se detendrá automáticamente Advertencia Nunca deje la bomba desatendida cuando use esta función ya que puede causar daños extremos a su inflable ya la bo...

Page 11: ...ro 8 Sensor eléctrico para la presión del aire 9 Tablero de control de la exhibición del LCD 10 Tablero de control del relais de energía 11 Otras piezas Garantía limitada de 2 años Para el uso recreativo las tarjetas eléctricas de control motor cargador están garantizados por 2 años Batería manguera de aire adaptadores de válvulas y bolsa de transporte están garantizados por 6 meses La garantía pa...

Page 12: ...e votre pompe ou votre batterie est complètement chargée avant de l utiliser La pompe a deux étapes et le son de chaque étape est différent La 2ème étape produira un bruit bruyant puisque les deux cylindres pompent Avant de brancher la pompe de la batterie assurez vous que la tension de la batterie est de 12 V et que le chargement maximal de la source d alimentation peut supporter un courant de 30...

Page 13: ...applications sont les mêmes que la version régulière de la pompe Valve de Boston ou Leafield Valve Certaines soupapes d air ont un diaphragme intégré pour empêcher l air de s échapper lors de la gonflement La soupape d air type Boston Leafield C7 utilise un diaphragme en caoutchouc intégré ou un diaphragme et un ressort ils provoqueront une contre pression excessive Lorsque vous gonflez des chambr...

Page 14: ...PSI la pompe commencera la 2ème étape seulement Si la pression de réglage est inférieure à la pression de la chambre la pompe ne s allume pas Protégez le gonfleur du sable et de l eau en le gardant dans le sac de transport fourni lorsqu il n est pas utilisé Si du sable ou de l eau entre dans le gonfleur et sur la limite de maintien du filtre à air la pompe à air sera endommagée et aucune garantie ...

Page 15: ...s périodes 1 mois ou plus endommagera la batterie Si vous avez complètement chargé la pompe juste avant de la ranger il ne devrait pas être nécessaire de la recharger pendant des mois Si vous voyez une icône de batterie faible sur l écran LCD rechargez la batterie dans les 24 heures Si la batterie ne supporte plus une charge la batterie devra peut être être remplacée dans la plupart des cas Travau...

Page 16: ...paiera les deux frais de transport si la demande de garantie est supérieure à 180 jours à compter de la date d achat Seamax donne seulement 2 ans de garantie pour les pompes que nous avons vendues Seamax servira toutes les pompes au Canada Adresse 120 11791 Machrina Way Richmond BC Canada Tél 604 277 7766 Veuillez conserver votre reçu et les étiquettes sur la pompe pour votre service de garantie N...

Reviews: