1021 

|

 1022 SMALL AIR COMPRESSOR

09

Error Code

Description/Symptoms

Probable Cause

Solution

E r 6

Motor START signal was not 
received by the Computer 

Control System (CCS).

NOTE: The motor may 
have been given a signal to 
start, however no pressure 
increase was detected in 
the Purge Tank. 

Major air leak in the system. Check compressor hoses and 

fittings for leaks; connect 

exercise machines to the 
compressor one at a time to 
check for leaks (see leak check 
procedure in the “Solution” 
column for 

E r 2, E r 8

Motor failure or Start 
circuit failure.

Disconnect, then reconnect the 
compressor to power supply. 
Listen for the motor start and 
the Solenoid Valve click:

• 

If the motor runs then 
check plumbing to 
ensure that all hoses are 
connected.

• 

If the motor does not start 
and the Solenoid Valve 
clicks, the motor is faulty 
and must be replaced.

• 

If the motor does not start 
and the Solenoid Valve 
does not click, the Circuit 
Board is faulty and must be 
replaced.

E r 7

Insufficient/no pressure 

build in Air Tanks.

Major air leak in one of the 
exercise machines or in the 
compressor plumbing.

Check compressor hoses and 

fittings for leaks; connect 

exercise machines to the 
compressor one at a time to 
check for leaks (see leak check 
procedure in the “Solution” 
column for 

E r 2, E r 8

E r 9

Air pressure building too 
slow.

Dirty or blocked Inlet-

Muffler Assembly.

Ensure the compressor located 
in a clean, dry, and well-
ventilated area; vents are not 

blocked. Replace Inlet-Muffler 

Assembly.

E r 10 

Formerly “E r A”
1030X, 1031X models only

Communication failure 
between the two computer 
Circuit Boards.

Damaged Communication 
Cable.

Replace the Communication 
Cable.

Circuit Board failure.

NOTE: Either Circuit Board 
can cause itself or the 
other to display the error.

Replace the Circuit Board(s). 

E r 11

Purge Valve leak detected.

Loose hose/fitting, o-ring 

failure, or loose canister.

Check for loose hose/fitting; 

ensure the o-ring is not 
damaged/torn and canister is 
threaded properly and snug on 
the bushing.

Содержание 1021

Страница 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Страница 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Страница 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Страница 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Страница 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Страница 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Страница 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Страница 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Страница 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Страница 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Страница 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Страница 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...