Use external temperature sensor (option)
An external NTC-sensor can be plugged into the bottom of the electrics tray (see Figure 21, page 28).
The temperature of the external sensor can be shown on the control panel instead of the steam boiler
temperature.
In the menu window touch the button “EXTERNAL SENSOR”.
menu window
touch
external sensor
window Triplette
external sensor
attached (°C)
external sensor
window Duette
external sensor
attached (°F)
touch
return to operational window
There is a filter-basket with NTC sensor available that will register the temperature in the coffee-bed
during extraction and can be helpful to check functioning of the different groups. Of course you can
also check the mix-water temperature with this item.
Figure 12. Temperature sensor in filter basket (mounted in bottomless portafilter).
Although the input of the “external sensor” is displayed without delay, the temperature shown will
always be lagging a bit w.r.t. the actual temperature at the sensor-tip as the probe-temperature needs
to adjust to the surrounding temperature. Response time of this sensor to 90% (of the temperature
difference) is appr. 1 second.