English

Introduction

This documentation is designed to enhance your understanding of the
capabilities of the Pulsair EasyEye by providing comprehensive and easy to
follow descriptions and instructions.

The names of buttons are presented in 

bold

 typeface.

Cross-references are presented in 

bold

italic

 typeface.

Unless stated to the contrary, positions and directions such as left, right,
front and rear are given with respect to the unit when viewed from the
front.

The fundamental basis upon which the Pulsair EasyEye operates are
discussed below.

Accuracy and Calibration

The Pulsair EasyEye calibration has undergone extensive clinical trials to
ensure that the instrument is reliable and accurate.

Pressure Variations

It is well known that IOP varies as a result of pulse, respiratory and diurnal
fluctuations. In addition blinking, squeezing, fluid intake, physical activity,
body position and even the direction of gaze can influence IOP.

Non-contact Tonometers take an instantaneous measurement that may
vary due to the pulsatile nature of the IOP. By taking four readings a more
accurate indication of IOP can be recorded.

Corneal Response to the Air Pulse

The response of the cornea to the air pulse is known as an 

event

. The

Pulsair EasyEye has been designed to use the gentlest possible air pulse to
achieve good quality events in the majority of eyes.

When a non event or bad event is detected by the Pulsair EasyEye it
displays 

ER

 and automatically switches to 

30+

 mode to create a slightly

higher pressure air pulse for the next reading.

Содержание Pulsair EasyEye

Страница 1: ......

Страница 2: ...formance and ease of use are Non contact measurement of Intra Ocular Pressure IOP Hand unit operation allowing IOP to be taken on virtually any patient Portability for domiciliary work or easy transport between different locations using the rechargeable battery option An automatic averaging system which displays the running average of readings taken Automatic 30 mode for reading high IOP A non eve...

Страница 3: ...specifications and other information contained in this document without prior notice Pulsair EasyEye is a registered Trademark of Keeler Limited 2001 Copyright Keeler Limited 2001 Printed in the UK October 2001 Applicable Standards Approvals EN 60601 1 EN 60601 1 2 UL 2601 1 EN8612 EN ISO 15004 1997 Patent Pending As part of our policy of continued product improvement we reserve the right to alter...

Страница 4: ... Short Form Instructions 11 Cover 11 Umbilical Cable 11 Wall Mount Power Socket 11 Desk Mount Power Socket 11 Overview of the Hand Unit 12 Display 12 Review Button 12 Right Left Eye Indicators 12 Change Eye Button 13 Non Event and 30 Indicator 13 Eyepiece 14 QuickPulse Indicator 14 QuickPulse Button 14 Demo Button 15 Guidance LED s 15 Puff Tube Lens 15 Getting Started 16 Mounting the Unit 17 Patie...

Страница 5: ...ter Paper 22 Eyecaps 23 The Rechargeable Battery 24 Maintenance and Cleaning 25 Bulb Change 26 Power Supply Unit 26 General 26 Optional Accessories and Spares 27 Troubleshooting 28 Spectral Radiance 29 Pulsair EasyEye Technical Data 30 Power Supply Unit 30 Notes 31 ...

Страница 6: ...the instrument is reliable and accurate Pressure Variations It is well known that IOP varies as a result of pulse respiratory and diurnal fluctuations In addition blinking squeezing fluid intake physical activity body position and even the direction of gaze can influence IOP Non contact Tonometers take an instantaneous measurement that may vary due to the pulsatile nature of the IOP By taking four...

Страница 7: ...aken for a patient or print a patient record before the unit is removed from the holster reviewing and printing can take place whilst the hand unit is located in the holster Warning Do not use the Pulsair EasyEye near mobile telephones as performance will be affected Advise patients to switch mobile telephones off before use Warning The Pulsair EasyEye maybe affected by Electro magnetic interferen...

Страница 8: ...ulsair EasyEye unit Orange Dust Cap fitted Power supply and four plugs Australian UK USA and Euro Dust Cover for unit Wall Mount Kit Two printer paper rolls 1 fitted and 1 replacement Two rubber eyecaps Blister pack of two spare bulbs One Users Guide Optional Extras supplied on request Rechargeable battery Hand carry bag ...

Страница 9: ...ht Base Unit Printer Test Eye Status Indicator Hand Unit On off Switch Serial Port Pulsair EasyEye Unit Cover Printer On Off Switch and Indicator Umbilical Cable Short Form Instructions Pull out Support Foot Wall Mount Power Socket for desk top operation use rear socket Front of Pulsair EasyEye ...

Страница 10: ...o Quickpulse Review Left Right Display Review Button Change Eye Button Right Left Eye Indicators Non Event 30 Indicator Eyepiece QuickPulse Mode Indicator QuickPulse Button Demo Button Pulsair EasyEye Hand Unit Puff Tube lens Guidance LED s ...

Страница 11: ...t is displayed below You need to manually write the patient s name and date on to the printout Test Eye Use the Test Eye located on the cover of the Pulsair EasyEye to practice taking readings Status Indicator Status Indicator displays Green light The Pulsair EasyEye is powered up and ready for use Flashing yellow light Rechargeable battery power is low The unit must be connected to the mains as s...

Страница 12: ...tructions The Short Form Instructions are located underneath the base unit you can access them from either side of the unit they are supplied fitted on the right side The Short Form Instructions show how to take patient readings Cover The cover lifts up to allow access to the printer and the rechargeable battery When closing ensure the cover clips into place Umbilical Cable The Umbilical Cable lin...

Страница 13: ...m together which equals 62 8 and dividing by the number of readings taken 4 This gives a final figure of 15 7 so the display shows 16 When all the required readings have been taken the figure displayed is the IOP that is recorded for the patient Review Button You can review the readings taken at any time Press the Review button The display shows the readings taken in the order they were taken the ...

Страница 14: ...an measure IOP s up to and a little over 30 mm Hg 30 which can measures IOP s up to 50 mm Hg If the Pulsair EasyEye detects a bad event or a non event it automatically switches to 30 mode this mode is only deactivated when the Change Eye button is pressed or the unit is returned to the holster When the bad event or non event occurs between valid readings the display shows ER and a flashing average...

Страница 15: ...d if so produces an air pulse Before invoking QuickPulse mode ensure that the correct image is seen through the eyepiece If this is the case and no air pulse occurs it may be that the particular eye is less reflective than normal Press the QuickPulse button It should now be easier to obtain a reading QuickPulse should always be used on post operative eyes with corneal scarring QuickPulse mode can ...

Страница 16: ...n can also help to indicate that the unit is in calibration A reading of 30 50 flashes alternatively in the display when the button is pressed To maintain accuracy we strongly recommend that the unit is calibrated annually Guidance LED s The two green LED s located on the front of the hand unit act as a guide when you are lining up the patients eye to take a reading Puff Tube Lens The puff tube le...

Страница 17: ...e Pulsair EasyEye and also the serial and part numbers which will be required for registration and re ordering 2 Remove the transit knob from the bottom of the Pulsair EasyEye unit as instructed by the label Note The transit knob should be replaced whenever the unit is transported 3 Take the power supply unit and replace the blanking plate with the appropriate mains plug adapter Alternatively you ...

Страница 18: ...and undo the two screws on the bottom of the unit remove the blue support foot 2 Turn the blue support foot through 180 and then screw it back on to the base unit at the opposite end 3 Position the supplied template on the wall and drill two holes Remove the template and fit the wall mounts using the screws x2 provided 4 Hook the keyhole openings on the back of the Pulsair EasyEye onto the screws ...

Страница 19: ...e the patient and instrument optics are not positioned under direct lighting i e spot lights or sunlight Ensure the patient s eyes are fully opened This helps to prevent squeezing where the patient unconsciously tenses their eyelids and increases IOP Throughout the reading process you should Allow the patient to blink at intervals in order to maintain the corneal tear film Instrument Preparation 1...

Страница 20: ...f dust or moisture which may have settled whilst the Pulsair EasyEye was not in use Taking Readings For quick reference please refer to the pull out short form instructions located underneath the Pulsair EasyEye unit Once the Pulsair EasyEye and the patient are prepared you are ready to take a reading 1 The Pulsair EasyEye is set to automatically select the right eye If you wish to select the left...

Страница 21: ...proximately 15mm a bow tie image appears Centralise this image on the central bar and the Pulsair EasyEye fires 8 If you see filaments you are too close Move back and repeat 9 Once you have taken a reading remain in the operating position wait a few seconds for the air chamber to refill When the bow tie image appears Pulsair EasyEye takes a subsequent reading Keeler recommends you take four readin...

Страница 22: ...nting the Results The Pulsair EasyEye has a built in printer which prints a patient s record once all the readings have been taken When the hand unit is returned to the holster the results are automatically printed if the printer is turned on If the printer is turned off when the hand unit is returned to the holster press the Printer on off switch to turn the printer on then press the Change Eye b...

Страница 23: ...is to remain unused for any length of time it should be switched off at the mains To Change the Printer Paper To change the printer paper 1 Lift the cover of the Pulsair EasyEye and remove the empty printer roll 2 Place the new roll of paper into the paper holder making sure the free end is loose at the top of the roll 3 Feed the free end of paper through the gap in the cover 4 Clip the cover back...

Страница 24: ...ssisting them in maintaining the correct positioning and distance from the cornea To use the eyecap place it around the puff tube lens The eyecap can remain on the hand unit when it is placed in the holster Eyecaps should only be used during training and not when recording patients IOPs Eyecaps are disposable and must only be used once ...

Страница 25: ...argeable battery and you require one please contact your local distributer The rechargeable battery must be charged for 12 14 hours before it is used for the first time To fit the battery 1 Lift the front cover of the Pulsair EasyEye and insert the rechargeable battery into the back of the compartment as shown below ensure the battery strap fits under the new battery Make sure the battery orientat...

Страница 26: ...tton bud with Isopropyl Alcohol 3 Move the tip of the bud around the lens in a circular motion 4 After one circle the bud should be discarded to avoid smearing on the lens 5 Look at the puff tube lens from the patient s side if traces of tear film can still be seen repeat above steps until clear 6 Replace the white plastic shroud and ensure the trim ring position is correct before tightening Note ...

Страница 27: ...lsair EasyEye and the mains If the outer insulation of the cable appears to be damaged discontinue use immediately Contact your local dealer for a replacement General Keep the instrument free from dust If the unit is to remain unused for any length of time turn the On Off switch to O and remove the power supply Use the dust cover to protect the unit Before using the Pulsair EasyEye again press the...

Страница 28: ...cessories and Spares Also available for the Pulsair EasyEye as optional extras A carrying bag Part No 2414 P 7003 Rechargeable battery Part No 2414 P 7000 Eyecaps Part No 2414 P 7002 Printer paper Part No 2208 L 7008 Bulbs Part No 1024 P 7156 ...

Страница 29: ... is fully charged if this does not solve the problem call your local distributer No red light visible through the puff tube when the unit is on Replace the bulb Paper jam Remove the paper reel and re insert as described on page 22 No power Check that the mains plug is switched on the power supply cable is inserted fully and that the On Off switch is turned to I If you are using a rechargeable batt...

Страница 30: ...air EasyEye Young children and persons with diseased eyes may be at higher risk The risk may also be increased if the person being examined has had any exposure with the same instrument or any other ophthalmic instrument using an intense visible light source during the previous 24 hours This will apply particularly if the eye has been exposed to retinal photography The time to reach a potential op...

Страница 31: ... 3 18kg 7lb 4 0kg inc battery 8 8lb Hand Unit weight 0 887 kg 1 95 lb Calibrated range 7 to 50 mm Hg Displayed accuracy 1 mm Hg Displayed scale Direct in mm Hg Length of umbilical cord 2 0 m 6 6 Complies with EN 60601 class II type BF Type BF definition as type B but with isolated or floating applied parts Power Supply Unit Power input 30 VA Input voltage 100 110 120 220 240 V Note 10 Input freque...

Страница 32: ...31 EP59 50399 Issue D English Notes ...

Страница 33: ...32 EP59 50399 Issue D English Pulsair EasyEye ...

Страница 34: ...0 353 7814 As part of our policy of continued product improvement we reserve the to alter and or amend specifications at any time without prior notice Approvals EN 60601 1 EN 60601 1 2 UL 2601 1 EN8612 EN ISO 15004 1997 Patent Pending 0088 Manufactured by Distributed by The CE mark on this product indicates it has been tested to and conforms with the provisions noted within the 93 42 eec Medical D...