Jazz Ultra Instruments by KEELER

2.2  WARNINGS AND CAUTIONS

Please note that the proper and safe functioning of our instruments is only guaranteed if 

both the instruments and their accessories are exclusively from Keeler Ltd. The use of other 

accessories may result in increased electromagnetic emissions or reduced electromagnetic 

immunity of the device and may lead to incorrect operation.
Observe the following precautions in order to ensure safe operation of the instruments.

WARNINGS

•  Never use the instrument if visibly damaged and periodically inspect it for signs of damage 

or misuse.

•  Check your Keeler product for signs of transport / storage damage prior to use.
•  Do not use in the presence of fl ammable gases / liquids, or in an oxygen rich environment.
•  US Federal Law restricts this device to sale by or on the order of a physician or practitioner.
•  This device is intended to be used only by suitably trained and authorised healthcare 

professionals.

•  This product should not be immersed in fl uid.

•  Instrument may become hot if used for extended periods of time.

CAUTION

•  Use only genuine Keeler approved parts and accessories or device safety and performance 

may be compromised.

•  Batteries must be inserted as per instructions – see section 4 on page 6

.

•  The product has been designed to function safely when at an ambient temperature 

b10°C and +35°C.

•  LEDs become hot during use; caution should be taken when replacing LEDs.

•  Keep out of the reach of children.
•  To prevent condensation from forming, allow instrument to come to room temperature 

before use.

•  For indoor use only (protect from moisture).
•  There are no user serviceable parts inside. Contact authorised service representative for 

further information.

•  Follow guidance on cleaning / routine maintenance to prevent personal injury / damage to 

equipment.

•  At product end of life dispose of in accordance with local environmental guidelines 

(WEEE).

Содержание Jazz Ultra

Страница 1: ...Jazz Ultra Instruments INSTRUCTIONS FOR USE A world without vision loss...

Страница 2: ......

Страница 3: ...7 5 OTOSCOPE AND ACCESSORIES 7 5 1 INSERTION AND REMOVAL OF EAR SPECULUM 7 5 2 INTRODUCTION OF EXTERNAL INSTRUMENTS INTO THE EAR 7 5 3 REPLACEMENT OF LED OTOSCOPE 8 6 OPHTHALMOSCOPE AND ACCESSORIES 8...

Страница 4: ...Community Humidity limitation Catalogue number Serial number Translation Medical device The Keeler Jazz Ultra Instruments are designed and built in conformity with Directive 93 42 EEC Regulation EU 20...

Страница 5: ...nts When set to a high power and magnification it can also be used to examine the anterior segment of the eye which includes the eyelids cornea sclera conjunctiva iris aqueous crystalline lens and ant...

Страница 6: ...actitioner This device is intended to be used only by suitably trained and authorised healthcare professionals This product should not be immersed in fluid Instrument may become hot if used for extend...

Страница 7: ...diately Do not mix battery types Do not disassemble or modify the battery There are no serviceable parts inside Dispose of batteries in line with local environmental regulations Tape over battery cont...

Страница 8: ...taminated with cerumen ear drainage or blood Dispose of safely 2 Manually clean all surfaces of the units using a suitable brush and de ionized water detergent solution 2 detergent by volume Ensure th...

Страница 9: ...head from the handle in an anti clockwise direction Remove the existing ring and replace with a new ring in the colour of your choice Screw the instrument heads back on in a clockwise direction 5 OTO...

Страница 10: ...Plus values are displayed in black digits and minus values in red digits 6 2 APERTURES AND FILTERS The following apertures and or filters may be selected by the Aperture and Filter Wheel Small Circle...

Страница 11: ...by authorised Keeler representatives Your Keeler product is guaranteed for 3 years and will be replaced or repaired free of charge subject to the following Any fault due to faulty manufacture The ins...

Страница 12: ...e very low and are not likely to cause any interference in nearby electronic equipment Class B Harmonic emissions IEC 61000 3 2 Not Applicable The Jazz Ultra Otoscope Ophthalmoscope is suitable for us...

Страница 13: ...z magnetic field IEC 61000 4 8 30 A m 30 A m Power frequency magnetic fields should be at a level characteristic of a typical location in a typical professional healthcare facility environment Note UT...

Страница 14: ...e location in which the Jazz Ultra Otoscope Ophthalmoscope is used exceeds the applicable RF compliance level above the Jazz Ultra Otoscope Ophthalmoscope should be observed to verify normal operation...

Страница 15: ...HNICAL SPECIFICATIONS Dimensions Otoscope 12cm x 3cm x 7 5cm H x D x W including handle and speculum Ophthalmoscope 13cm x 3cm x 3cm H x D x W including handle Weight Otoscope 68gm including handle wi...

Страница 16: ...P 7108 Jazz 4mm Specula Pack of 100 1514 P 7116 Jazz 5mm Specula Pack of 100 1514 P 7124 12 PACKAGING AND DISPOSAL INFORMATION Disposal of old electrical and electronic equipment This symbol on the p...

Страница 17: ...15 EN Jazz Ultra Instruments by KEELER...

Страница 18: ......

Страница 19: ......

Страница 20: ...2021 USA Sales Office Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd P...

Отзывы: