Jazz Ultra Instruments by KEELER

1.  INDICATIONS FOR USE 

These devices are intended to be used only by suitably trained and authorised healthcare 

professionals.

CAUTION: Federal Law restricts this device to sale by or on the order of a 

physician or practitioner.

Intended use / purpose of instrument

Keeler Jazz Ultra Otoscopes are indicated for the examination of the health of the external 

auditory canal, the tympanic membrane, and the middle ear. Otoscopy can aid in the detection 

of ear conditions, including but not limited to earache, ear infection, hearing loss, ringing in the 

ears, infl ammation, and foreign bodies.
Keeler Jazz Ultra Ophthalmoscopes are indicated for examining the posterior segment of 

the eye referred to as the fundus, to aid in the screening and diagnosis of retinal pathology 

including, but not limited to, diseases such as cataracts, papilloedema, glaucomatous disc 

cupping, diabetic retinopathy, hypertensive retinopathy and retinal detachments. When set to 

a high power and magnifi cation, it can also be used to examine the anterior segment of the 

eye, which includes the eyelids, cornea, sclera, conjunctiva, iris, aqueous, crystalline lens and 

anterior vitreous.

2.  SAFETY

2.1  PHOTOTOXICITY

CAUTION: The light emitted from this instrument is potentially hazardous. 

The longer the duration of exposure, the greater the risk of ocular 

damage. Exposure to light from this instrument when operated at 

maximum intensity will exceed the safety guideline after 21 minutes.
While no acute optical radiation hazards have been identifi ed for 

Diagnostic Instruments, we recommend keeping the intensity of the light 

reaching the patient’s retina to the minimum possible for the respective 

diagnosis. Children, people with aphakia and people suffering from 

eye conditions are most at risk. An increased risk may also occur if the 

retina is exposed to the same or a similar device with a visible light 

source within 24 hours. This applies, in particular, if the retina has been 

photographed with a fl ashbulb in advance. 
Keeler Ltd shall on request, provide the user with a graph showing the 

relative spectral output of the instrument.

Содержание Jazz Ultra

Страница 1: ...Jazz Ultra Instruments INSTRUCTIONS FOR USE A world without vision loss...

Страница 2: ......

Страница 3: ...7 5 OTOSCOPE AND ACCESSORIES 7 5 1 INSERTION AND REMOVAL OF EAR SPECULUM 7 5 2 INTRODUCTION OF EXTERNAL INSTRUMENTS INTO THE EAR 7 5 3 REPLACEMENT OF LED OTOSCOPE 8 6 OPHTHALMOSCOPE AND ACCESSORIES 8...

Страница 4: ...Community Humidity limitation Catalogue number Serial number Translation Medical device The Keeler Jazz Ultra Instruments are designed and built in conformity with Directive 93 42 EEC Regulation EU 20...

Страница 5: ...nts When set to a high power and magnification it can also be used to examine the anterior segment of the eye which includes the eyelids cornea sclera conjunctiva iris aqueous crystalline lens and ant...

Страница 6: ...actitioner This device is intended to be used only by suitably trained and authorised healthcare professionals This product should not be immersed in fluid Instrument may become hot if used for extend...

Страница 7: ...diately Do not mix battery types Do not disassemble or modify the battery There are no serviceable parts inside Dispose of batteries in line with local environmental regulations Tape over battery cont...

Страница 8: ...taminated with cerumen ear drainage or blood Dispose of safely 2 Manually clean all surfaces of the units using a suitable brush and de ionized water detergent solution 2 detergent by volume Ensure th...

Страница 9: ...head from the handle in an anti clockwise direction Remove the existing ring and replace with a new ring in the colour of your choice Screw the instrument heads back on in a clockwise direction 5 OTO...

Страница 10: ...Plus values are displayed in black digits and minus values in red digits 6 2 APERTURES AND FILTERS The following apertures and or filters may be selected by the Aperture and Filter Wheel Small Circle...

Страница 11: ...by authorised Keeler representatives Your Keeler product is guaranteed for 3 years and will be replaced or repaired free of charge subject to the following Any fault due to faulty manufacture The ins...

Страница 12: ...e very low and are not likely to cause any interference in nearby electronic equipment Class B Harmonic emissions IEC 61000 3 2 Not Applicable The Jazz Ultra Otoscope Ophthalmoscope is suitable for us...

Страница 13: ...z magnetic field IEC 61000 4 8 30 A m 30 A m Power frequency magnetic fields should be at a level characteristic of a typical location in a typical professional healthcare facility environment Note UT...

Страница 14: ...e location in which the Jazz Ultra Otoscope Ophthalmoscope is used exceeds the applicable RF compliance level above the Jazz Ultra Otoscope Ophthalmoscope should be observed to verify normal operation...

Страница 15: ...HNICAL SPECIFICATIONS Dimensions Otoscope 12cm x 3cm x 7 5cm H x D x W including handle and speculum Ophthalmoscope 13cm x 3cm x 3cm H x D x W including handle Weight Otoscope 68gm including handle wi...

Страница 16: ...P 7108 Jazz 4mm Specula Pack of 100 1514 P 7116 Jazz 5mm Specula Pack of 100 1514 P 7124 12 PACKAGING AND DISPOSAL INFORMATION Disposal of old electrical and electronic equipment This symbol on the p...

Страница 17: ...15 EN Jazz Ultra Instruments by KEELER...

Страница 18: ......

Страница 19: ......

Страница 20: ...2021 USA Sales Office Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd P...

Отзывы: