10 Technical data
10.1 Operating panel OP 350/C-1100
10.1.1
In general
Nominal supply voltage:
24 V DC (voltage limits according to EN
61131-2)
Max. switch-on current:
10 A
Maximum power consumption:
30 W
Power consumption own consumption:
12 W
Max. power consumption (USB module):
14 W at 12 V DC (optional)
Max. power consumption (RFID module):
1 W at 12 V DC (optional)
Max. power consumption (digital inputs):
3 W at 24 V DC (optional)
Programming language:
kemro.view.standard
Display:
12.1“ TFT, 256,000 colors
●
Resolution:
800 x 600 pixel (SVGA)
Touchscreen:
Yes
●
Functional principle:
analog resistive
Membrane keypad:
48 membrane keys with embossing and tactile
feedback, some with LEDs and labeling strips.
1 Power LED
10.1.2
Environmental conditions
Operating temperature:
+5 °C to +55 °C
Storage temperature:
-40 °C to 70 °C
Relative humidity of air:
5 % to 95 % (non condensing)
Vibration resistance:
According to EN 61131-2
Shock resistance:
According to EN 61131-2
Equipment class:
III (according to EN 61131-2)
Protection class:
●
IP 54 front side (if installed correctly)
●
IP 20 back side
10.1.3
Digital inputs
Number of inputs:
16 (DI0-DI15) (not EN 61131-2 compliant)
Rated voltage:
24 V DC
Applied contact current:
5 mA (supply exclusively by Vout)
Galvanic isolation:
No
Status display:
None
Min. update cycle:
60 ms
10.1.4
Interfaces
Serial interface:
●
Type:
RS-485-A
●
Baud rate:
115 kbit/s
Operating panel
Technical data
© KEBA 2009
Project engineering manual V2.00
39