P30
UDP commands
UDP Programmers Guide V2.01
18
© KEBA
Field
Contents
Additional Description
Tmo CT
uint32
Possible values:
0; 1 - 860400
Timeout in seconds before the current setting
defined by the last
currtime
command will
be applied.
Setenergy
uint32
Possible values:
0; 1 - 999999999
Energy value in 0.1 Wh defined by the last
setenergy
command (
setenergy
100000
specifies 10 kWh). Max. value is
99999999.9 Wh (higher values will cause a
counter overflow).
Output
uint32
Possible values:
0; 1; 10 - 150
Show the setting of the UDP command
output
.
Input
0; 1
State of the input X1; For further information
concerning the input X1, see the "installation
manual".
Serial
String (8 chars)
Serial number of the device.
Sec
uint32
Current state of the system clock in seconds
from the last startup of the device.
3.2.4
UDP command: report 3
Command structure
Command
Parameters
Additional Description
report 3
-
-
Reply structure
Field
Contents
Additional Description
ID
3
ID of the report
U1
int (3 digits)
Measured voltage value on phase 1 in V
U2
int (3 digits)
Measured voltage value on phase 2 in V
U3
int (3 digits)
Measured voltage value on phase 3 in V
I1
int (5 digits)
Measured current value on phase 1 in mA
I2
int (5 digits)
Measured current value on phase 2 in mA
I3
int (5 digits)
Measured current value on phase 3 in mA
P
uint32 (8 digits)
Power in mW (effective power).
PF
int (4 digits)
Possible values:
0 - 1000
Current power factor (cosphi). The unit dis-
played is not % but 0.1%.
E pres
uint32
Possible values:
0 - 999999999
Energy transferred in the current charging
session in 0.1 Wh. This value is reset at the
beginning of a new charging session.
Max. value is 99999999.9 Wh (higher values
will cause a counter overflow).