P30 x-series
Functions
Configuration manual V4.02
29
© KEBA
4.3
OCPP backend
The charging station offers the option of being connected to a central man-
agement system via the Open Charge Point Protocol (OCPP). OCPP, as an
open application protocol, makes it possible to connect any central manage-
ment system to the charging station regardless of the manufacturer or sup-
plier.
When connecting to an OCPP backend, note the following:
●
It is recommended that the master charging station on the network be
assigned a static IP address based on the MAC address of the device.
●
Since the OCPP backend is usually not in the same network, the charg-
ing station must be assigned a "public IP address" which is routed to the
internal IP address (NAT).
●
The firewall must be configured so that a communication between the
charging station and the OCPP backend is possible.
●
For a connection via VPN, the IP address of the VPN must be specified
in the configuration for the downlink.
●
In the case of a GSM connection, it may be necessary for the required
ports to be activated by the cellular service provider.
Ports for communication via OCPP
For communication with an OCPP backend, the following ports must be en-
abled in the network:
Port
Protocol
Definition
Description
Custom
(1025 -
65535)
TCP
Can be reached externally
(incoming)
OCPP Charge Point Service: This
service is related to the OCPP
backend.
●
The port can be freely selected
or it is specified by the OCPP
backend. However, the port
may only be located in the
range from 1025 to 65535.
●
The selected port must be
configured on the charging
station.
Custom
TCP
Access to external (outgo-
ing)
Port at which the OCPP backend
can be reached.
123
UDP
Incoming and outgoing
Port for the timer server of the
charging station.
Содержание KeContact P30 x-series
Страница 1: ...KeContact P30 x series Konfigurationshandbuch Configuration manual ...
Страница 2: ......
Страница 3: ...KeContact P30 x series Ladestation Konfigurationshandbuch V 4 02 Originalbetriebsanleitung ...
Страница 39: ...KeContact P30 x series Charging station Configuration manual V 4 02 Translation of the original manual ...
Страница 74: ...P30 x series Index Configuration manual V4 02 36 KEBA W Web interface 18 WLAN 12 WLAN Access Point Hotspot 13 ...
Страница 75: ......
Страница 76: ...KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria www keba com 98412 ...