KC-P30
Technical data
Installation manual V3.28
53
© KEBA
12
Technical data
12.1
General
Charge mode:
Mode 3 in accordance with IEC 61851-1
AC charging
Overvoltage category:
III in accordance with EN 60664
Protection class:
I
Protection class:
IP54
Protection against mechanical impact:
IK08 (except for cylinder lock)
Rated short-time withstand current:
< 10 kA (effective value in accordance with
EN 61439-1)
Residual direct current detecting device
(RDC-DD):
> 6 mA (characteristic in accordance with
IEC 62955, < 10 s)
Ventilation during charging:
Not supported
12.2
Power supply
Power consumption
e-series
Rated supply voltage (Europe):
230 V
Internal consumption:
Idling: 2 W, plugged in: 3 W, charging: 5.5 W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase
Line frequency:
50 Hz
Mains forms:
TT / TN / IT
Power supply
b-series
/
c-series
Rated supply voltage (Europe):
3 x 230 V / 400 V
Internal consumption:
Idling: 3 W, plugged in: 4.5 W, charging:
6.5 W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase or 3-phase
Line frequency:
50 Hz
Mains forms:
TT / TN / IT
Power supply
x-series
Rated supply voltage (Europe):
3 x 230 V / 400 V
Internal consumption:
Idling: 4 W, plugged in: 5 W, charging: 7 W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase or 3-phase
Line frequency:
50 Hz
Mains forms:
TT / TN / IT