E10 Smart Energy Meter
Set a fixed IP address for your Energy meter
V1.01
10
© KEBA 2023
Information
●
If the P30 x-series is used as the DHCP server, it is recommended to
set the KeContact E10 IP address to a high value like “192.168.42.254”.
In this case it is unlikely that the DHCP Server from the P30 x-series as-
signs this IP address to another client (charging station) in the network.
1)
Important:
Disable DHCP by changing Register
267
to value “
0
”. This
will permanently set the IP address to the selected value.
2) Restart the KeContact E10 either via the reset button or changing Regis-
ter
61615
to value “
1
”.
3) The Modbus Mechanic software tool should loose the connection and
KeContact E10 should be reachable under the new IP address. You can
verify this with the “Advanced IP Scanner” tool.