GB - 27
Operating of the unit
5.6
Special Adjustments
The following parameters serve to optimize the drive and adaption onto certain
applications. These adjustments can be ignored at the initial startup.
This function protects the frequency inverter against switching off by overcurrent
during the acceleration ramp. When the ramp reaches the adjusted value here,
then it is stopped so long until the current decreases again. CP.2 displays "LAS"
at active function.
Adjustment range:
10...200 %, 200%=oFF up to case D
10...200%; >150% = oFF from case E
Resolution:
1 %
Factory setting:
140 %
Customer adjustment:
_______ %
This function protects the frequency inverter against switching off due to
overcurrent during constant output frequency. When exceeding the adjusted
value here, the output frequency is reduced until the value drops below the
adjusted value. CP. 2 displays "SSL" at active function.
Adjustment range:
10...200 %, 200%=oFF
up to case D
10...200%; >150% = oFF
from case E
Resolution:
1 %
Factory Setting:
200 %
Customer adjustment:
_______ %
Max. ramp current
Max. constant
current
t
f
set
f
real
on
off
on
off
C.15
C.14
LAD-stop
Current limit
t
t
t
Содержание COMBIVERT M4
Страница 1: ...00 M4 00B K101 05 2003 D BETRIEBSANLEITUNG KEB COMBIVERT M4 GB INSTRUCTION MANUAL COMBIVERT 0 75 3 kW ...
Страница 40: ...D 40 ...