![KEB COMBIVERT F6 series Скачать руководство пользователя страница 83](http://html.mh-extra.com/html/keb/combivert-f6-series/combivert-f6-series_instructions-for-use-manual_660366083.webp)
83
OIL-cOOLeD DeVIceS
5.2 Oil-cooled devices
The following instructions must be observed when using the device.
5.2.1 Heat sink and operating pressure for oil-cooled devices
Design system
Material
max. operating pressure connection
Aluminium heat sink
Aluminium 3.3206
10 bar
NOTICE
Deformation of the heat sink!
►
In order to avoid a deformation of the heat sink and the damages
thereby, the indicated maximum operating pressure may not be
exceeded briefly also by pressure peaks.
►
The Pressure Equipment Directive 2014/68/EU on pressure equip-
ment must be observed!
5.2.2 Oil requirements
General requirements for the oil:
requirement
Description
Characteristic of the oil
Hydraulic oil HLP 46 (ISO VG 46)
Oils with appropriate prop-
erties
• Mobil DTE 25
• Shell Tellus Oil 46
• Castrol Hyspin ZZ 46
Or similar oils
Table 43:
Oil requirements
Special requirements for open and half-open cooling systems:
requirement
Description
Impurities
Mechanical impurities in half-open cooling systems can be counteracted by using
appropriate filters.
Organic materials
The contamination with organic materials must be kept as small as possible, be-
cause separate slime can be caused by this
Table 44:
Special requirements for open and semi-open cooling systems for oil coolers
Damage to the device resulting from clogged heat sinks or other obvious usage
failures leads to the loss of warranty claims.