4.2.6 connection and use of a braking resistor
cAUTION
Fire risk by using brake resistors !
► The risk of fire can be significantly reduced by using „intrinsically
safe braking resistors“ or by using suitable monitoring functions /
circuits.
NOTICE
Destruction of the frequency inverter if the vale has fallen below
the minimum brake resistance value!
►
The minimum brake resistance value must not fall below!
„Device data of the 400 V devices“
cAUTION
Hot surfaces caused by load of the braking resistor!
burning of the skin!
►
Cover hot surfaces safe-to-touch.
►
Before touching, check the surface.
►
If necessary, attach warning signs on the system.
4.2.6.1 Installation instructions for side-mounted braking resistors
Instructions for the installation of intrinsically safe brak-
ing resistors
https://www.keb.de/fileadmin/media/Manuals/dr/ma_dr_
safe-braking-resistors-20106652_en.pdf
Chapter „Installation in-
structions“.
71
cONNecTION OF THe POWer UNIT