64
5.2.6
Use in combination with COMBIVIS HMI Runtime
COMBIVIS HMI Runtime can be of course configured to communicate with the CON-
TROL Runtime.
The C6 HMI LC includes the Gateway which is then used as communication inter-
face.
The COMBIVIS studio HMI project must be configured to communicate with a gener-
ic CODESYS controller inserting in the “Real Time DB” resource the driver called
“CODESYS” as shown in the following figure.
The protocol uses a socket to communicate with the CONTROL Runtime through the
Gateway component.
The Station must be configured to connect to “localhost”. The Device name is the
one shown by the programming system COMBIVIS studio 6 when connected on-line
with the C6 HMI LC device from the “Communication settings” window as shown in
the following figure.
The COMBIVIS studio HMI Station Properties will result as following.