background image

PREVENTIVE MAINTENANCE CLEANING 

CHART

AVOID SERVICE CHECKLIST

Before calling for service, review this list. It may save you
both time and expense. This list includes common occur-
rences that are not the result of defective workmanship or
materials in this appliance.

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. In the
event that your Miraclean

®

Griddle, under warranty, needs

repairs other than routine cleaning, you are requested to con-
tact KEATING OF CHICAGO, INC. (1-800 KEATING).

THERMOSTAT CALIBRATION

Calibration is not covered under warranty.

Tools: Accurate surface thermometer

Standard screwdriver

1.

Turn the exhaust system ON.

2.

Turn on the griddle with thermostat set at 300°F. Allow
burners to cycle on and off three times. (Approximately
60 minutes.)

3.

Place accurate thermometer on surface over thermostat
bulb. Use the inverted “V” on the front of the griddle plate
to locate thermostat bulb. Place the surface ther-
mometer about half waytoward the back of the plate.

4.

When burners cycle off, the griddle is up to temperature.
If temperature is within 25°F of thermostat setting,
remove knob. Loosen four screws in the thermostat dial
plate. Replace knob. Reset the dial plate to match the
thermometer reading.

Thermostat calibration

Thermostat knob removed to reveal calibration screws.

5.

Remove the knob to tighten screws on dial plate and
replace the knob.

For calibration over a 50°F difference, contact a qualified
service company.

DO NOT ADJUST THE THERMOSTAT SET
SCREW - IT VOIDS ANY WARRANTY ON 

CONDITIONING THE 

MIRACLEAN

®

GRIDDLE PLATE

The Miraclean

®

Griddle plate has been “seasoned” at the

factory. The Miraclean

®

surface when heated creates a thin

layer of chrome oxide which acts as a releasing agent for
food product. You may feel that you need to recondition
your griddle surface.

1.  Follow cleaning instructions on page 5.

2.  Heat the MIRACLEAN

®

to 400°F for one hour.

3.  Lower thermostat to 350°F, allowing the MIRACLEAN

®

to

cool to about 350°F, as is evident when griddle cycles on
or surface thermometer indicates correct temperature.

4.  Lightly coat the MIRACLEAN

®

surface with griddle oil.

NOTE: 

Despite the food releasing properties, the chrome surface is not a true

“non-stick” surface. For best cooking results and product appearance, use grid-
dle oil for products that require the surface to be conditioned.

PARTS ORDERING

Parts may be ordered by part number by calling Keating at 1-
800-KEATING or your service company.  You may also order
on-line at Keating’s part store, www.keatingofchicago.com.

Refer to the Keating MIRACLEAN

®

Griddle Limited Warranty

for complete service and ordering information.

The model/serial plate is located inside the cabinet. Remove
grease drawer. The model and serial numbers are necessary
when ordering.

7

TIME OPERATOR/OWNER

FRAME

At Least

Clean MIRACLEAN

®

Griddle surface.

Daily

Drain and clean grease drawer.

Completely wipe down MIRACLEAN

®

Griddle cabinet.

At Least

Check MIRACLEAN

®

Griddle surface

Monthly*

to insure proper maintenance. 
(Review proper cooking procedures.)

Check calibration of thermostats.

Review operating instructions
received with MIRACLEAN

®

griddle.

Every

Clean gas valve vent tube.

6 Months*

Check burner manifold pressure.

At Least

QUALIFIED SERVICE PERSONNEL ONLY

Yearly*

Have MIRACLEAN

®

griddle completely 

checked, calibrated, tested, cleaned, etc. 
by qualified service personnel. Be sure to 
check color and height of pilot flame.

*High production facilities should be checked more often. Contact the

factory or a local service company to perform maintenance and repairs.

PROBLEM

SOLUTION

Miraclean

®

Griddle

• Is the gas connected?

does not operate:

• Is the gas supply turned on?

• Is the gas valve knob in the ON posi-

tion?

• Is the pilot lit?

• Is the switch turned on?

• Is the thermostat set at the desired 

position?

PART

Содержание SERIES 2000

Страница 1: ...UBLE SHOOT CHART 10 THERMOSTAT REMOVAL REPLACEMENT 11 12 SERVICE 11 13 WIRING DIAGRAM 14 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty period should...

Страница 2: ...AY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPANE GAS...

Страница 3: ...T RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inches 152mm from any c...

Страница 4: ...ure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DIS CONNECT DEVICES For an appliance equipped with casters The installation shall be ma...

Страница 5: ...te to determine if the burner is set up for the proper type gas before connecting the quick disconnect or piping from the building gas supply pipe a Gas pressure at manifold NATURAL GAS 4 0 in W C b G...

Страница 6: ...fers conducted heat to the food being cooked more rapidly than other griddle plates because the food is placed directly on the metal surface It is the understanding of this rapid heat transfer that pe...

Страница 7: ...nventional griddles at least start at lower tem peratures You may be able to work the tempera ture up as you become accustomed to the more rapid cooking of the Miraclean Griddle 2 Cook as usual but af...

Страница 8: ...an surface is very hard With proper care the MIRACLEAN surface and its unique cooking prop erties will last for many years Damage done to the Miraclean surface is irreplacable NEVER USE A GRIDDLE STON...

Страница 9: ...ition your griddle surface 1 Follow cleaning instructions on page 5 2 Heat the MIRACLEAN to 400 F for one hour 3 Lower thermostat to 350 F allowing the MIRACLEAN to cool to about 350 F as is evident w...

Страница 10: ...GAS VALVE 004803 11 SCREW FOR TAN KNOB 004805 NOT SHOWN ITEM DESCRIPTION P N 1 CONTROL PANEL INSERT 1 800 KEATING 2 DIAL PLATE 200 500 F 060105 3 THERMOSTAT 550 F 023897 THERMOSTAT KNOB BLACK 038368...

Страница 11: ...INSERT REFERENCE ONLY 6 BURNER REFERENCE ONLY 7 AIR SHUTTERS 031477 8 MAIN SUPPLY GAS VALVE 3 4 not shown above ITEM DESCRIPTION PART NUMBER 9 MAIN GAS PIPE 3 4 REFERENCE ONLY 10 STREET ELBOW 3 4 0057...

Страница 12: ...is in pilot position c Thermostat is not turned on d Low gas presssure e Gas valve failure a Put ON OFF switch to ON position b Turn knob to ON position c Turn thermostat to desired temperature d Set...

Страница 13: ...T 1 Lower the control panel by removing the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its nor...

Страница 14: ...1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas Valve knob...

Страница 15: ...mum output is observed Then extinguish pilot and observe meter 2 Dropout of automatic pilot magnet sound should be audi ble should occur between 120 millivolts and 30 millivolts If dropout occurs outs...

Страница 16: ...GRIDDLE WIRING DIAGRAM SERIES 2000 CONTROL PANEL THERMOSTAT ON OFF SWITCH WIRING DETAIL ORG BLK BLK BLK thermostat RED TO TH TP ON GAS VALVE WHITE TO TP TERMINAL ON GAS VALVE TO TH ON GAS VALVE TO TH...

Страница 17: ......

Страница 18: ..._________________________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ______________...

Отзывы: