ASSEMBLY INSTRUCTIONS FOR GRIDDLE
STAND ON CASTERS
(THERE IS NO TOP ON THIS STAND)
PLACING MIRACLEAN
®
GRIDDLE IN OPERATION
(When all previous instructions have been completed).
Check the serial plate to determine if the burner is set
up for the proper type gas before connecting the quick-
disconnect or piping from the building gas supply pipe.
a.
Gas pressure at manifold
NATURAL GAS – 4.0 in. W.C.
b.
Gas pressure at manifold
LP GAS – 10 in. W.C. (2.49kPa).
c.
Maximum incoming gas pressure
NATURAL GAS – 7 in. W.C. (2.01kPa).
d.
Maximum incoming gas pressure
LP GAS – 11 in. W.C. (2.98kPa).
1.
Connect incoming gas.
3