background image

Improper installation,
adjustment, alteration, 
service or maintenance 
can cause property 
damage, injury or death.
Read the installation, 
operating and maintenance
instructions thoroughly 
before installing or 
servicing this equipment.

WARNIN

G

Improper installation

can cause damage,

injury or death.

D

Shock

Burns

Gas

NOT INSTALLED, OPERATED AND MAIN-
TAINED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS,
THIS PRODUCT COULD EXPOSE YOU
TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE
DEATH OR SERIOUS ILLNESS AND
WHICH ARE KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH
DEFECTS OR OTHER REPRODUCTIVE
HARM.

PROPANE GAS MAY EVENTUALLY LOSE
ITS ODOR AND PRECAUTIONS SHOULD BE
TAKEN TO ASSURE THAT PROPANE GAS IS
NOT PRESENT EVEN THOUGH YOU DO
NOT DETECT AN ODOR. IF THERE IS ANY
DOUBT, YOU SHOULD CALL YOUR LOCAL
PROPANE GAS SUPPLIER FOR ASSIS-
TANCE.

FOR YOUR SAFETY

Do not store or use
gasoline or other
flammable vapors or
liquids in the vicinity
of this or any other
appliance.

Purchaser should post in a prominent location instructions to

be followed in the event the user smells gas. This information

shall be obtained by consulting the local gas supplier.

THE EQUIPMENT IS TO BE
INSTALLED TO COMPLY WITH THE
BASIC PLUMBING CODE OF THE
BUILDING OFFICIALS AND CODE
ADMINISTRATORS INTERNATIONAL,
INC. (BOCA) AND THE FOOD SERV-
ICE SANITATION MANUAL OF THE
FOOD AND DRUG ADMINISTRATION
(FDA).

WARNING

Do not store flammable

liquids near this or any

other appliance.

Содержание SERIES 2000

Страница 1: ...UBLE SHOOT CHART 10 THERMOSTAT REMOVAL REPLACEMENT 11 12 SERVICE 11 13 WIRING DIAGRAM 14 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty period should...

Страница 2: ...AY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPANE GAS...

Страница 3: ...T RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inches 152mm from any c...

Страница 4: ...ure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DIS CONNECT DEVICES For an appliance equipped with casters The installation shall be ma...

Страница 5: ...te to determine if the burner is set up for the proper type gas before connecting the quick disconnect or piping from the building gas supply pipe a Gas pressure at manifold NATURAL GAS 4 0 in W C b G...

Страница 6: ...fers conducted heat to the food being cooked more rapidly than other griddle plates because the food is placed directly on the metal surface It is the understanding of this rapid heat transfer that pe...

Страница 7: ...nventional griddles at least start at lower tem peratures You may be able to work the tempera ture up as you become accustomed to the more rapid cooking of the Miraclean Griddle 2 Cook as usual but af...

Страница 8: ...an surface is very hard With proper care the MIRACLEAN surface and its unique cooking prop erties will last for many years Damage done to the Miraclean surface is irreplacable NEVER USE A GRIDDLE STON...

Страница 9: ...ition your griddle surface 1 Follow cleaning instructions on page 5 2 Heat the MIRACLEAN to 400 F for one hour 3 Lower thermostat to 350 F allowing the MIRACLEAN to cool to about 350 F as is evident w...

Страница 10: ...GAS VALVE 004803 11 SCREW FOR TAN KNOB 004805 NOT SHOWN ITEM DESCRIPTION P N 1 CONTROL PANEL INSERT 1 800 KEATING 2 DIAL PLATE 200 500 F 060105 3 THERMOSTAT 550 F 023897 THERMOSTAT KNOB BLACK 038368...

Страница 11: ...INSERT REFERENCE ONLY 6 BURNER REFERENCE ONLY 7 AIR SHUTTERS 031477 8 MAIN SUPPLY GAS VALVE 3 4 not shown above ITEM DESCRIPTION PART NUMBER 9 MAIN GAS PIPE 3 4 REFERENCE ONLY 10 STREET ELBOW 3 4 0057...

Страница 12: ...is in pilot position c Thermostat is not turned on d Low gas presssure e Gas valve failure a Put ON OFF switch to ON position b Turn knob to ON position c Turn thermostat to desired temperature d Set...

Страница 13: ...T 1 Lower the control panel by removing the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its nor...

Страница 14: ...1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas Valve knob...

Страница 15: ...mum output is observed Then extinguish pilot and observe meter 2 Dropout of automatic pilot magnet sound should be audi ble should occur between 120 millivolts and 30 millivolts If dropout occurs outs...

Страница 16: ...GRIDDLE WIRING DIAGRAM SERIES 2000 CONTROL PANEL THERMOSTAT ON OFF SWITCH WIRING DETAIL ORG BLK BLK BLK thermostat RED TO TH TP ON GAS VALVE WHITE TO TP TERMINAL ON GAS VALVE TO TH ON GAS VALVE TO TH...

Страница 17: ......

Страница 18: ..._________________________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ______________...

Отзывы: