PREVENTATIVE MAINTENANCE
Preventative maintenance should be performed during
& after each use of the fi lter. Following preventative
maintenance procedures will help to keep your fi lter
working effi ciently. Proper care & servicing will lead to
years of quality performance.
Familiarize yourself with the proper fi ltering
procedure prior to attempting to fi lter:
1. To remove water, stir oil until bubbling stops; water
will clog fi lter paper pores.
2. Use only one sheet of fi lter paper properly sealed
under hold down ring.
3. Do NOT turn on fat melt without oil in fi lter tub.
4. Use a drain clean out rod if partial or full blockage
in fryer drain is suspected.
5. If fi lter was used for fryer boil out, run oil through
fi lter to lubricate motor/pump.
6. Clean fi lter and all components after each use. Do
not permit oil to remain in fi lter drawer; it will clog the
pump.
7. Verify all lights and controls operate.
8. Adhere to operating instructions in sequence given
for proper fi ltration.
9. Prepare fi lter for next use by using new fi lter paper
and Acidox Powder for each fryer.
SERVICE
DISASSEMBLY
You will need:
Adjustable wrench "Stubby" screwdriver
Standard pliers Standard screwdriver
Servicing should only be performed by qualifi ed and
licensed service companies. Always disconnect the
electrical power cable before attempting any service
THE FILTER MAY BE HOT; USE CARE WHILE SER-
VICING. AS A SAFETY PRECAUTION, IT IS RECOM-
MENDED YOU DRAIN OIL FROM THE FILTER VES-
SEL BEFORE PERFORMING ANY SERVICING.
A. MELT AND/OR PUMP INDICATOR LIGHTS
Removal:
1. Disconnect fi lter from electrical power source.
2. Feel front end panel from bottom to locate rear of
defective indicator light. Note two tangs that extend
slightly beyond indicator light barrel diameter. Use
a standard pliers to squeeze tangs together and
pull indicator light free from panel. If indicator light
doesn’t release, squeeze tighter and break barrel to
release electrical leads. Discard broken pieces.
Replacement:
1. If necessary, clip off electrical leads as close as
possible to indicator light. If leads were clipped, trim
off insulation 1/8 inch from end.
2. With electrical leads extending through panel
front, press them into recesses at rear of replace-
ment indicator light to secure them in place. Press
indicator light into panel until tangs engage to se-
cure indicator light to panel.
B. MELT AND/OR PUMP ON/OFF SWITCH
Removal:
1. Disconnect fi lter from electrical power source.
2. Unscrew nut securing defective switch to panel.
Push switch in to release from panel. Remove name-
plate from front of panel.
3. Access to rear of switch through bottom hole
under front end panel.
4. Disconnect leads from switch. Tag leads as they
are disconnected to assure, during replacement,
they are reconnected to the proper switch terminals.
Replacement:
1. Connect tagged electrical leads to replacement
switch.