manualshive.com logo in svg
background image

1-800-KEATING

 

|

   

PORTABLE FILTER

SERVICE PARTS ORDERING

Parts may be ordered by part number by calling Keating at 1-800-KEATING or your service company. We recommend 
using genuine Keating Replacement Parts - engineered and manufactured specifi cally to meet exact specifi cations 
and requirements for Keating equipment.

Refer to the Keating Filter Limited Warranty for complete service and ordering information.

The model/serial plate is located on the side of the unit. The model and serial numbers are necessary when 
ordering.

WARNING AND OPERATING PLATES

All warning and operating plates on the Portable Filter should be in place at all times. If plates are damaged or 
lost, replace them immediately.

PARTS LIST - PORTABLE FILTER

MODEL LB100

9

 DESCRIPTION 

P/N

  CASTER 3" SWIVEL (after 2003) 

000626

  CASTER 3" RIGID (pre 2003) 

000627

  COVER for LB100 
     2000 Series 

056273

     Pre 2000 Series, Optional 

000503

 FILTER 

SCREEN 

LB100 (12 1/4 dia.) 

000591

 INDICATING 

LIGHT 

     Amber 

004158

     Red 

000525

  HANDLE for COVER 

004542

  HEAT PLATE, 500 W 115V 

000596

  HEAT WRAP TAPE, 4' for LB/PC Filters 

012055

 HI-LIMIT 

SENSOR 

060164

  HOLD DOWN RING HANDLE 

052817

  HOLD DOWN RING LB100 

000576

  HOLD DOWN RING LB100 (after 1/2003) 

054803

  HOSE, 4' w/fi ttings & Stiffner Spring for
     PC14 (for LB Filters prior to 2/3/93) 

000569

  HOSE, 5' w/fi ttings for
     LB Filters after 2/3/93) 

018157

 INSULATION 

BOARD 

007694

  NOZZLE, 90º with Handle for LB/UFF Filters 011816
  POWER CORD, 6' with plug 

055241

 

**PUMP/MOTOR (after 11/88) 

008196

  **PUMP/MOTOR (after 2003) 

038176

  SPRING for T HANDLE 

006656

 STRAINER 

BASKET 

LB100 (old style) 

000668

 SWITCH 

(Pump/Off/Melt) 

000521

  SWITCH REVERSING (2-Way Pump) 

000527

 TERMINAL BOARD 

000639

 TERMINAL BOARD INSULATION 

000263

**Call 1-800-KEATING with serial number to determine correct 
part #.

 DESCRIPTION 

P/N

 ACIDOX 

POWDER 

     (30 lb. case, 60 individual packages) 

037524

  DRAIN CLEAN OUT ROD 

004622

  FILTER PAPER  
     LB100 (60 papers)  

058783

       LB165 or LB200 (60 papers) 

058781

     PC14 (60 papers) 

058779

  PADDLE METAL SPOON 

029152

  SEA POWDER (for boiling out fryers)
     4 jar case 

000394

     4 jar case (6 cases and up) 

000395

SUPPLIES

Содержание PC 14

Страница 1: ......

Страница 2: ...9902091 9902091 i HOT FLUID DO NOT FILL BEYOND MAXIMUM FILL LINE LOCATED IN THE FRYER VESSEL...

Страница 3: ...or damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage incurred in transit IMPORTANT This merchandise has been thoroughly inspected and carefully packed befor...

Страница 4: ...ner basket NOTE Hold down ring makes a gasket like seal on filter paper Filter paper must be placed edge to edge from front to back overlapping on sides Filter Paper must be smooth and flat under hold...

Страница 5: ...ilters with two way pump do NOT place wand in cold zone of fryer pot as it may pick up crumbs other debris and excessively clog filter paper 10 Operate pump for approximately thirty seconds after filt...

Страница 6: ...b and pipes to free system of solidi fied shortening Reset motor before attempting filtering reset button is located on rear of pump motor WARRANTY REPAIRS Keating s 1 year parts labor warranty begins...

Страница 7: ...t motor before attempting filtering reset button is located on rear of pump motor b Place components in tub per the following 1 Filter screen on the very bottom 2 Filter paper over filter screen Lie i...

Страница 8: ...ttempting any service THE FILTER MAY BE HOT USE CARE WHILE SER VICING AS A SAFETY PRECAUTION IT IS RECOM MENDED YOU DRAIN OIL FROM THE FILTER VES SEL BEFORE PERFORMING ANY SERVICING A MELT AND OR PUMP...

Страница 9: ...ilter and rest filter on oil absorbing rags on its back end 3 Remove bottom cover attaching screws remove bottom cover 4 Remove electrical leads from defective heater element s Tag leads as they are d...

Страница 10: ...al power source NOTE Remove all oil from filter vessel Filter must be positioned on its end to access heat tape 2 Raise front power cord end of filter and rest filter on oil absorbing rags on its back...

Страница 11: ...591 INDICATING LIGHT Amber 004158 Red 000525 HANDLE for COVER 004542 HEAT PLATE 500 W 115V 000596 HEAT WRAP TAPE 4 for LB PC Filters 012055 HI LIMIT SENSOR 060164 HOLD DOWN RING HANDLE 052817 HOLD DOW...

Страница 12: ...HANDLE T 010628 HEAT PLATE 500W 115V 000596 HEAT WRAP WIRE 4 100W 120V 012055 HI LIMIT SENSOR 060164 HOLD DOWN RING 011370 HOSE 4 with nozzle fittings 017640 INDICATING LIGHT Red 000525 INSULATION BO...

Страница 13: ...1 800 KEATING PORTABLE FILTER WIRING DIAGRAM LB100 LB165 LB200 1 WAY PUMP PUMP PART 008196 LB100 LB165 LB200 2 WAY PUMP PUMP PART 055173 1988 2002 11...

Страница 14: ...keatingofchicago com 12 WIRING DIAGRAM LB165 LB200 1 WAY PUMP 2004 Series PUMP PART 055173 LB165 LB200 1 WAY PUMP After 2005 PUMP PART 055173...

Страница 15: ...1 800 KEATING PORTABLE FILTER 13 WIRING DIAGRAM LB165 LB200 1 WAY PUMP 2003 Series PUMP PART 052982 LB165 LB200 2 WAY PUMP After 2004 PUMP PART 055173...

Страница 16: ...keatingofchicago com 14 WIRING DIAGRAM LB200 1 WAY PUMP PUMP PART 010567 1993 LB200 2 WAY PUMP PUMP PART 010567 1993...

Страница 17: ...1 800 KEATING PORTABLE FILTER 15 WIRING DIAGRAM PC 14...

Страница 18: ...nty against latent defects Exclusions The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Страница 19: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...