manualshive.com logo in svg
background image

     

keatingofchicago.com

CLEANING THE UTENSILS

Spatulas

 should be hand washed 

in mild to medium strength deter-
gent and towel dried. 

NOTE:

 Avoid contact with Chlorine 

or bleach, it will discolor the 
steel spatula. Rubbing the spat-
ula with vegetable oil will slow 
discoloration.

Rinse 

scraper

 and carefully 

wipe blade with a dry cloth. 
Cover blade with plastic protec-
tion cover when not in use.

Rinse Palmetto brush until 
clean.

NOTE: BECAUSE OF THE SUPERIOR MIRACLEAN® 
SURFACE, THE ONLY TOOLS YOU WILL EVER NEED 
TO CLEAN THE GRIDDLE ARE A NATURAL BRISTLE 
BRUSH AND A KEATING SCRAPER.

 

 

NEVER USE A GRIDDLE STONE, BRICK OR SCREEN 

TO CLEAN THE MIRACLEAN® SURFACE.

  

 

DAMAGE DONE TO THE MIRACLEAN® SURFACE BY 

GRIDDLE STONE, BRICK OR SCREEN WILL VOID THE 
WARRANTY.

 

 

THE DAMAGE DONE TO THE MIRACLEAN® SURFACE 

IS IRREPARABLE.

 

NEVER USE ICE TO COOL THE MIRACLEAN® 

SURFACE. USE OF ICE MAY WARP THE MIRACLEAN® 
SURFACE.

 

 

USE ONLY KEATING SUPPLIED CLEANING TOOLS 

AND KLENZER.

 

USE ONLY KEATING SPATULAS.

 

DO NOT WASH STEEL SPATULA WITH CHLORINE OR 

BLEACH AS IT WILL DISCOLOR.

NOTE: 

Keating Klenzer MSDS is available on our 

website.

SHUTDOWN

1. For 208 - 240 Volt Unit: Turn each thermostat fully 
counterclockwise and On/Off switch to “OFF” position.

For 480 Volt Unit: Turn thermostat knob to “OFF” 
position.

MAINTENANCE

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. 
In the event that your MIRACLEAN® Electric Griddle, 
under warranty, needs repairs other than routine 
maintenance or cleaning, you are required to contact 
Keating of Chicago (at 1-800-KEATING) before calling a 
local service company.

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily, week-
ly, monthly and yearly intervals as necessary. Following 
preventive maintenance procedures will help keep your 
MIRACLEAN® working effi ciently. Proper care and servic-
ing will lead to years of quality performance.

TIME FRAME

OPERATOR/OWNER

AT LEAST 

DAILY*

• Check lights and controls.

• Clean griddle surface.

• Drain and clean grease drawer.

• Completely wipe down griddle
   cabinet.

AT LEAST 

MONTHLY*

• Check condition of Miraclean® 
   surface and review proper 
   cooking procedures.

• Check calibration of 
   thermostat(s).

• Review operating instructions
   received with Miraclean® griddle.

TIME FRAME

QUALIFIED SERVICE PERSONNEL

AT LEAST 

YEARLY*

• Have Miraclean® Griddle 
   completely checked, calibrated, 
   tested, cleaned, etc. by qualifi ed 
   service personnel.

*

High production facilities should be checked more often.

Contact the factory or a local service company to perform 
maintenance and repairs.

A. Griddle Surface

With proper care, the MIRACLEAN® surface and its 
unique cooking properties will last for many years. 
However, nicks or dents in the griddle surface may 
cause the griddle surface to lift from the depressed 
area. If nicks are close together, the surface may raise 
and be torn when a spatula or scraper is used. Care 
should be taken, as the damage done is irreparable. 
See Figure 3-3. 

6

HAMBURGER 
SPATULA

GRIDDLE
SCRAPER

Содержание miraclean 2000 series

Страница 1: ...formed it is in your interest to obtain and keep all receipts Keating commercial griddles are not intended for household use As continuous product improvement occurs specifications may be changed with...

Страница 2: ...r appliance 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions...

Страница 3: ...rvice personnel Operating information for Keating equipment has been prepared for use by qualified and or authorized personnel Keating equipment is made in the USA and has American sizes of hardware A...

Страница 4: ...ment will void the warranty Before uncrating check equipment carefully for damage INSTALLATION Installation must conform with local codes or in absence of local codes with the current National Electri...

Страница 5: ...ddle terminal connections to the appropriate wiring diagram for the griddle see pages 12 14 Wiring Diagram to see if the griddle is connected three phase or single phase All wires cords plugs receptac...

Страница 6: ...ing MIRACLEAN Griddles are designed to provide maximum production efficiency and deliver high quality food products Follow cooking procedures below 1 For 208 240 Volt Unit Set ON OFF switch to ON posi...

Страница 7: ...and how the surface can be damaged Proper use of the utensils supplied with your MIRACLEAN Griddle will prevent surface damage Figure 3 3 NOTE Damage done to the MIRACLEAN surface is irreparable and...

Страница 8: ...ur MIRACLEAN Electric Griddle under warranty needs repairs other than routine maintenance or cleaning you are required to contact Keating of Chicago at 1 800 KEATING before calling a local service com...

Страница 9: ...e 4 1 rotate dial plate to match thermometer reading and tighten screws NOTE Calibration is not covered under warranty CLEANING Proper care should be taken to fully clean the griddle on a regular basi...

Страница 10: ...hough element is heating a Indicating light is faulty a Replace indicating light Temperature of griddle is erratic a Thermostat out of calibration b Thermostat bulb improperly placed c Exhaust problem...

Страница 11: ...9521 THERMOSTAT REPLACEMENT KIT 400 F 035954 THERMOSTAT DIAL PLATE 400 F 034870 THERMOSTAT DIAL PLATE 550 F 060105 THERMOSTAT KNOB 400 F BLACK 060612 THERMOSTAT KNOB 550 F BLACK 038368 B LIGHT 050255...

Страница 12: ...005913 1 006228 1 006229 1 3 INSULATION BOARD 002489 1 002493 1 002490 1 4 HEATING ELEMENT PAN 020553 1 020554 1 020556 1 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 1 1 1 6 HEATING ELEMENT HOLD...

Страница 13: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 11 ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND on Casters There is no top on this stand...

Страница 14: ...keatingofchicago com 12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Страница 15: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 13 208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS...

Страница 16: ...keatingofchicago com 14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Страница 17: ...S 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 36x24 3 ELEMENTS 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1...

Страница 18: ...4 24 24 41 240 10 7 26 26 26 45 36x30 3 ELEMENTS 3000W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 10 7 34 34 22 52 220 12 0 36 36 24 55 240 14 3 39 39 26 60 42x30 48x30 4 E...

Страница 19: ...W AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 13 4 43 43 28 65 220 15 0 45 45 30 68 240 17 9 49 49 32 75 42x36 48x36 4 ELEMENTS 3750W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS...

Страница 20: ......

Страница 21: ......

Страница 22: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Отзывы: