ITEM

DESCRIPTION

PART 

NUMBER

QTY

24" DEEP

QTY

30" DEEP

QTY

33" DEEP

1

HEATING ELEMENT

  2300W, 220V

002478

1

  3000W, 220V

002483

1

  3750W, 220V

002487

1

  3300W, 220V (HIGH INPUT, TEPPANYAKI)

002482

1

  4370W, 220V (HIGH INPUT)

002480

1

  3000W, 440V

013270

1

  3750W, 480V

006337

1

  3300W, 480V

005567

1

  WASHER, FLAT, #10 7/16" OD

059502

2

2

2

  WASHER, LCKG INT TOOTH HI-TEMP #10

011562

4

4

4

  NUT 10-32

000361

2

2

2

2

HEAT DISPERSION PLATE

005913

1

006228

1

006229

1

3

INSULATION BOARD

002489

1

002493

1

002490

1

4

HEATING ELEMENT PAN

020553

1

020554

1

020556

1

5

HEATING ELEMENT BULB
  HOLD DOWN “M” BRACKET

008593

1

1

1

6

HEATING ELEMENT 
  HOLD DOWN BRACKET

029352

3

4

5

7

3/8" NUT, WASHER, LOCK-WASHER 
  AND PALNUT

028736

8

10

12

NOTE:

 Quantities shown are for each element. See Specifi cations on pages 15 to 17 for the number of elements for your 

griddle.

TO REPLACE THERMOSTAT

• 

Loosen nuts (#7)

• 

Loosen nuts to Dispersion Plate 

   (if needed)

• 

Slide thermostat bulb through slots 

   pictured in items 2, 3, & 4.

• 

With bulb tight against the plate, 

   tighten all nuts.

Figure 6-3
HEATING ELEMENT ASSEMBLY

Содержание miraclean 2000 series

Страница 1: ...formed it is in your interest to obtain and keep all receipts Keating commercial griddles are not intended for household use As continuous product improvement occurs specifications may be changed with...

Страница 2: ...r appliance 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions...

Страница 3: ...rvice personnel Operating information for Keating equipment has been prepared for use by qualified and or authorized personnel Keating equipment is made in the USA and has American sizes of hardware A...

Страница 4: ...ment will void the warranty Before uncrating check equipment carefully for damage INSTALLATION Installation must conform with local codes or in absence of local codes with the current National Electri...

Страница 5: ...ddle terminal connections to the appropriate wiring diagram for the griddle see pages 12 14 Wiring Diagram to see if the griddle is connected three phase or single phase All wires cords plugs receptac...

Страница 6: ...ing MIRACLEAN Griddles are designed to provide maximum production efficiency and deliver high quality food products Follow cooking procedures below 1 For 208 240 Volt Unit Set ON OFF switch to ON posi...

Страница 7: ...and how the surface can be damaged Proper use of the utensils supplied with your MIRACLEAN Griddle will prevent surface damage Figure 3 3 NOTE Damage done to the MIRACLEAN surface is irreparable and...

Страница 8: ...ur MIRACLEAN Electric Griddle under warranty needs repairs other than routine maintenance or cleaning you are required to contact Keating of Chicago at 1 800 KEATING before calling a local service com...

Страница 9: ...e 4 1 rotate dial plate to match thermometer reading and tighten screws NOTE Calibration is not covered under warranty CLEANING Proper care should be taken to fully clean the griddle on a regular basi...

Страница 10: ...hough element is heating a Indicating light is faulty a Replace indicating light Temperature of griddle is erratic a Thermostat out of calibration b Thermostat bulb improperly placed c Exhaust problem...

Страница 11: ...9521 THERMOSTAT REPLACEMENT KIT 400 F 035954 THERMOSTAT DIAL PLATE 400 F 034870 THERMOSTAT DIAL PLATE 550 F 060105 THERMOSTAT KNOB 400 F BLACK 060612 THERMOSTAT KNOB 550 F BLACK 038368 B LIGHT 050255...

Страница 12: ...005913 1 006228 1 006229 1 3 INSULATION BOARD 002489 1 002493 1 002490 1 4 HEATING ELEMENT PAN 020553 1 020554 1 020556 1 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 1 1 1 6 HEATING ELEMENT HOLD...

Страница 13: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 11 ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND on Casters There is no top on this stand...

Страница 14: ...keatingofchicago com 12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Страница 15: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 13 208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS...

Страница 16: ...keatingofchicago com 14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Страница 17: ...S 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 36x24 3 ELEMENTS 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1...

Страница 18: ...4 24 24 41 240 10 7 26 26 26 45 36x30 3 ELEMENTS 3000W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 10 7 34 34 22 52 220 12 0 36 36 24 55 240 14 3 39 39 26 60 42x30 48x30 4 E...

Страница 19: ...W AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 13 4 43 43 28 65 220 15 0 45 45 30 68 240 17 9 49 49 32 75 42x36 48x36 4 ELEMENTS 3750W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS...

Страница 20: ......

Страница 21: ......

Страница 22: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Отзывы: