background image

5

In most cases the health department will not allow a
direct connection between the cooker drain and the
floor receptical. Contact your local health department for
specific information in your area.

III OPERATION

FILLING

NOTE:

Before filling the Pasta System make certain the

vessel is sanitized, dry and the drain valve is completely 
closed. 

Figure 3-1

Manual Water Fill Level

When the water fill toggle switch (located between the
green and blue indicating lights) is turned on, the Pasta
System vessel automatically will be filled to the proper
level. If the vessel is being manually filled with water
from a faucet or through the manual fill button, fill to just
below the overflow deck. The black manual fill button is
located to the right of the blue water fill indicating light.

THERMOSTATS

The Keating pasta cooker has two thermostats. This is
to allow maximum control of the boil. The system is
designed so that both thermostats will function together
when called for but one thermostat will act as primary
and hold the water at a rolling boil during cooking as
well as idle time. The two thermostats allow the user to
have complete control over the cooking process.

The right side thermostat will only activate if the left side
thermostat is active. From a cold start all elements and
thermostats will be on and heat the water to a rolling
boil. Once the water has reached a rolling boil the right
side 

(secondary) 

thermostat will turn off and the left side

thermostat 

(primary) 

will hold the water at a rolling boil.

When product to be cooked is dropped into the pasta
cooker the drop in temperature depends on the
temperature spread between the two thermostats as
determined by the user.

If adding product does not turn on the secondary
thermostat and the water falls below a rolling boil,
increase the setting slightly on the secondary
thermostat. It is not recommended that there be less
than a twenty degree difference between the two

thermostats. Having less than a twenty degree
difference will increase the possibility of a boil over and
cause the pasta cooker to short cycle. The
recommended starting temperatures for the cooker are
212°F (98.8°C) for the primary and 190°F (87.8°C) for
the secondary thermostat. Using these settings with the
knowledge of the operation of this system, the user can
fine tune the settings to fit his specific operation.

CONTROL PANEL FEATURES

Figure 3-2

Custom Pasta System Electric Control Panel

AMBER

–shows the power is on.

GREEN

–shows the secondary (right)

thermostat is calling for heat from the
center element(s).

BLUE

–shows water is filling into the

Pasta System vessel through the Pasta
System water solenoid valve.

NOTE: 

The black manual water fill button is located to

the right of the blue indicating light.

THE AUTO-FILL SYSTEM

The water temperature must not exceed 120°F (48.8°C).
Control of the water level is fully automatic with the auto-fill
system. The water level is controlled by two circuit boards
attached to the two water level sensors located on the front
of the pot below the spashdeck. Once the water switch is
turned to ON, the pasta cooker will start to fill with water.
The heating elements will not turn on until the water level is
above the bottom sensor. This is an automatic water safety
built into every pasta cooker. This safety prevents the pasta
cooker from accidental heat damage due to low or no water.
The bottom sensor is the low water cut off. The top sensor
is the water level control. Both sensors should be cleaned
on a regular basis to prevent water deposits from interfering
with the sensor reaction. Cleaning should be done with the
brush up and down the sensor tube located on the right side
of the splashdeck.

COOKING

Keating Electric Custom Pasta Systems are designed to
provide maximum production efficiency and deliver high
quality food products. Low-temperature cooking and highly
polished stainless steel mean greater energy savings. Two
thermostats are used to provide instant recovery and to
save energy while water is boiling. The secondary (right)

Содержание INSTANT RECOVERY SERIES 2009

Страница 1: ...CTION VII WIRING DIAGRAMS 14 ELECTRIC PASTA WITHOUT TIMERS 15 14 ELECTRIC PASTA WITH DIGITAL TIMERS 16 14 ELECTRIC PASTA WITH 138 BLACK DIAL TIMERS 17 14 ELECTRIC PASTA WITH BASKET LIFT DIGITAL TIMERS...

Страница 2: ...er of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE...

Страница 3: ...ic timers Low water safety shutoff 1 full port front drain valve on 14 11 4 for 18 and larger High temperature limit control with manual reset Patented accurate temperature control system 2 F Ideal 35...

Страница 4: ...anel before servicing NEVER leave a pasta system unattended during operation NEVER move a pasta system when full of hot water NEVER introduce objects or liquids into pasta system while operational whi...

Страница 5: ...a claim with the carrier since such damage is the carrier s responsibility By following these instructions carefully we guarantee our full support of your claims to protect you against loss from conce...

Страница 6: ...device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edition for connectors for movable gas appliances Quick disconnect dev...

Страница 7: ...difference between the two thermostats Having less than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting tempe...

Страница 8: ...t Lift Model 1 Fill Pasta System as described on page 6 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on...

Страница 9: ...turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more...

Страница 10: ...any maintenance problem is directly or indirectly related to cleanliness NOTE Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty NOTE Use of sod...

Страница 11: ...cleaning Control of the water level is fully automatic with the auto fill system The water level is controlled by two circuit boards and two sensors The sensors are located in the tube on the right si...

Страница 12: ...it The potentionmeter adjusts the sensitivity of the probe Adjusting this sensor will not increase the depth of the water Improper adjustments can effect the operation of the cooker and cause damage...

Страница 13: ...not minutes or seconds 1 Reset the timer see pages 8 9 Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 037390 sold per foot Breakers continue to trip 1 Ensure all wires to the c...

Страница 14: ...echanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tig...

Страница 15: ...Fig 7 1 Custom Pasta System Electric Control Panel 1 2 3 2 4 5 6 6 7 7 ORDERING PARTS Parts may be ordered by part number by calling Keating at 1 800 KEATING or your local servce company You may also...

Страница 16: ...SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN 004376 1 1 1 1 220 110V...

Страница 17: ...15 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...

Страница 18: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 16...

Страница 19: ...17 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 20: ...18 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Страница 21: ...19 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 22: ...20 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 23: ...21 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 24: ......

Страница 25: ...______________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE...

Отзывы: