Thermostat Bulb Positioning

Keating’s patented thermostat application is
accurate within 2°F of the dial setting between
250°F and 350°F. This accuracy is attained only
if the thermostat bulb is placed properly against
the heat transfer tube. A single thickness of
paper should be pulled through between the
tube and the bulb with medium resistance to
quickly and accurately test for proper bulb
placement and pressure.

1)

If the bulb is too tight, the paper
will either not pull through or it will
tear.
A fryer with a thermostat bulb that
is too tight will short cycle.

Short Cycle

: The thermostat will cycle rapidly

while the fryer is in the idle mode; the
temperature will be erratic and fuel will be
wasted.

2) If the bulb is too loose, the paper

will slip through with little or no
resistance. A fryer with a
thermostat bulb that is too loose
will overshoot or cycle long.

Overshoot:

The thermostat takes a long time to

cycle and then misses its preset temperature
by 20°F - 40°F yielding a poor quality
product.

Thermostat Bulb Positioning

c. Replace control panel back.
d. Replace control panel.
e. Replace flame switch bulb.

(See diagram below)*

9.

Connect electric power source (except for
AA and CMG models), turn on gas and
pilots.

10.

Boil-out fryer.

11.

Refill fryer with oil to the “Fill Level” line.

12.

Start and preheat fryer, and calibrate
thermostat.

www.keatingofchicago.com

1-800-KEATING

S E R V I C E   I N S T R U C T I O N S

Insert bulb through holes in bracket and slot in clip. With FSC bulb Ferrule on runner pilot tube side of clip, press

clip down hooking it over bottom end of bracket.

PRESS

FERRULE SLEEVE

BULB

PILOT RUNNER TUBE

“ENGAGED”

Typical runner pilot tube and bracket

Clip #021810

Screw “A”

#016650

Screw “B”

#010776

Fasten clip in place 

using screw “A” and/or

screw “B” as shown.

page 3

Part #031289

Rev. 1

ECO 2110

Date 6/11/98

*Flame Switch Installation