23
For your convenience, RC-6S has a data storage and load program. It can store five
battery data representing the respective specifications of batteries. You can call back the
data when charging or discharging without setting up the program again. Press
START/ENTER key to make it blink, and use INC or DEC to set up the parameter.
Setting of the parameter in the screen will not affect the charge and
discharge process. They just present the specification of the
batteries. The example is NiMH battery pack, including 12 cells, the
capacity is 3000mAh.
Set up the charge current in the manual mode, or current limit in the
auto mode. Press INC and EDC key simultaneously to make the
current field blink to switch the charge mode.
Set up the discharge current and final voltage.
Set up the charge/ discharge sequence and cycle number.
Saving the data.
PROGRAM SELECT
SAVE DATA
Start
Enter
14.4V 3000mAh
Voltage Data
Number
Type of
battery
capacity
SAVE [01] NiMH
NiMH CJARGE AT*
CURLIMIT 5.0A
D E C
I N C
D E C
I N C
Batt Type Stop
NiMH DISCHARGE *
1.0A 11.0V
D E C
I N C
D E C
I N C
NiMH CYCLE *
DCHG>GHG 3
D E C
I N C
D E C
I N C
D E C
I N C
Start
Enter
‘>3 seconds’
DATA STO RAGE PROGRAM
SAVE
…
DATA STOR AGE PROGRAM