22
Set up the charge current on the left and nominal voltage on
the right. Range of current is 0.1-5.0A,the voltage should
match the battery being charged. Press START/ENTER key
for more than 3 seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press
START/ENTER key again to store the parameter value you
set. Press BATT TYPE/STOP key to end the program.
NiMH CYCLE
DCHG>CHG 3
DE C
I NC
D EC
I NC
Batt Type
Stop
Start
Enter
‘>3 seconds’
D>C 022:45 00890
Battery
type
Elapsed
time
Battery
voltage
Charged
capacity
scharge
current
NiMH 1.0A 7.42V
Pb DISCHARGE
DCHG>CHG 3
DEC
I NC
D EC
I N C
Batt Type
Stop
Start
Enter
‘>3 seconds’
DSC 022:43 00682
Number
type
Elapsed
time
Battery
voltage
Discharged
capacity
Discharge
current
Pb-6 0.4A 12.59V
Set up the charge current on the left and nominal voltage on
the right. Range of discharge current is 0.1-5.0A,the voltage
should match the battery being charged. Press
START/ENTER key for more than 3 seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press
START/ENTER key again to store the parameter value you
set. Press BATT TYPE/STOP key to end the program.
Disch arging oft he Pb battery
CHARGING OF THE Pb BATTER Y
CHARGING OF THE Pb BATTERY