INFORMATION MESSAGES
No.
Info. message
Description
Remedy
205
Connection audio module faulty Communication between control and module /
display has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact
your Customer Service.
206
Connection inside display faulty
210
Low battery charge, please
renew
Button cell (CR-2032) of the control board dis-
charged.
Replace the button cell (CR-2032).
212
Connection RGB module faulty Communication between control and bus
module has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact
your Customer Service.
213
SD card missing
No SD card in the audio module.
Insert an original SD card.
See chapter: Recording to an SD card/Removing the SD
card.
214
SD card unreadable
SD card defective, incompatible content.
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter: Recording to an
SD card/Removing the SD card. If the fault persists, contact
your Customer Service.
216
Error voltage supply, please
check
Power supply to the mainboard varies
Check power supply to the mainboard.
217
No voice files on the SD card,
pleas check.
No voice files on the SD card found.
Rebuild voice folder on the SD card. If necessary replace
original SD card.
220
OW to many sensors
General OneWire sensor error.
Contact your Customer Service.
221
OW sensor Typ B missing
222
OW sensor Typ S missing
223
OW sensor read error
224
Check tubes and temperature
sensor in the door (delta>12)
Temperature difference to high - between the
one wire sensors.
Check tubes and thermal sensors in the door. Contact your
Customer Service.
228
Check tubes and temperature
sensor in the door (temp<30)
Minimum temperature is not reached or is
fallen below in operation mode.
Check tubes and thermal sensors in the door. Contact your
Customer Service.
229
Pleas close the door, check
exhaust air
Temperature rise of 1,5 degrees in 18 sec-
onds.
Close door. Check exhaust air.
Содержание Tower mon amie
Страница 1: ...Инструкция по эксплуатации ...
Страница 2: ......
Страница 44: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 44 Замечания ...
Страница 45: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 45 Замечания ...
Страница 46: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 46 Замечания ...
Страница 47: ......