И н с т р у к ц и я п о э к с п л у а т а ц и и
|
Tower mon amie
40
System messages
ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior display.
No.
Status message
Description
Remedy
01
Excess temperature bimetal
Bimetal switch triggers.
Check the air-intake/air-discharge system. Let the sunbed
cool down.
02
Maximum tanning time!
Enabling signal from coin-box system comes
in longer than the time value approved under
“Maximum tanning time” (voltage remains
connected)
Disconnect from the coin-box system.
03
Excess temperature exhaust
fan!
Bimetal switch in the fan triggers.
Make sure the fan runs freely. Check the air-intake/air-
discharge system. Let the sunbed cool down.
12
KBL7 Hardware error Input-
Controller
Mainboard defective.
Contact your Customer Service.
13
Maximum write cycle flash
memory reached
Maximum write cycle flash memory reached. Contact your Customer Service.
14
Error! SD card read error
(CRC fault)
Update via SD card failed (CRC fault).
SD card check / replace.
15
Error! no access to the SD
card
Update via SD card failed (access error).
SD card check / replace
17
Parameter storage not found,
please connect and restart
Parameter storage not found, please con-
nect and restart.
Check connector parameter storage. If necessary replace
parameter storage.
18
Parameter storage no valid
serial number
Parameter storage no valid serial number.
Contact your Customer Service.
19
CAN-BUS: Interior display V1
is incompatible
CAN-BUS operators incompatible.
Use CAN-BUS operaters V2.
20
CAN-BUS: preSelection dis-
play V1 is incompatible
21
CAN-BUS: audio module full
V1 is incompatible
22
CAN-BUS: RGB module V1
ist incompatible
23
Parameter storage write error
Parameter storage write error.
Check connector parameter storage. If necessary replace
parameter storage.
24
Parameter storage read error
Parameter storage read error.
Check connector parameter storage. If necessary replace
parameter storage.
25
Frequency detection: detec-
tion failed!
Frequency detection failed.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.
26
Frequency detection: power
supply connection faulty (con-
nector X6/E6)!
Frequency detection failed. No mains volt-
age.
Check mainboard connector X6/E6.
Содержание Tower mon amie
Страница 1: ...Инструкция по эксплуатации ...
Страница 2: ......
Страница 44: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 44 Замечания ...
Страница 45: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 45 Замечания ...
Страница 46: ...И н с т р у к ц и я п о э к с п л у а т а ц и и Tower mon amie 46 Замечания ...
Страница 47: ......