52
Operating Instructions KBL 7900/KBL 7000/KBL Convertible
8.6 Error messages
Error message
“Abluft“ oder
“Windschalter“
This error message is displayed on the operating panel and
can be acknowledged by pressing the “Stop“ key. Prior to this,
service staff has to fi nd the reasons of these error messages.
Possible reasons can be:
• temperature in the unit is too high
• exhaust vent system is defectiv
Error message
“Ende der
Besonnung“
„End of tanning
session“
This message will be displayed after 40 minutes of uninterrupted
operation of the tanning system.
By turning off the coin-operated system this message is
acknowledged.
E01BUS:ABL
There is not any data link between the controller board and the
revolution control...
Reason: defective or not connected I²C revolution control.
E02:BUS:TMP
Reason: defective or not connected I²C temperature sensor.
Solution: press the START key. The blower is running with max.
revolution during the temperature controll.
BUS-Error
Daten line of the Bus I²C-Bus is disturbed
— 220 V is missing at MP3-Player or Audio Switch
— Bus connector at MP3-Player in wrong position
E04:BUS:VOIC
Reason: There is not any data link between the controller board
and the MP3 player Voice.
Solution: press the START key. The controller is working as one
w/o megaVoice.
Reason:
— missing soldering bridge on MP3-Player megaVoice,
— SD card not readable
— formating or wrong inserted,
— Plug at MP3 iInterface or at I²C Audio switch is
inserted uncorrect.
E05BUS:REL
Confi guration error: I²C-Relay board (8) an I²C Relais board (2)
at the same time connected.