27
Operating Instructions KBL 7900/KBL 7000/KBL Convertible
Close the bed
5.9 Exhaust air system
With each tube replacement, check the connecting hoses
visually. Defective hoses have to be exchanged.
Check connecting
hoses
A clean and trouble-free exhaust air system prevents the
apparatus from overheating.
Maintenance
5.10 Air-conditioning unit and condensate pump
Checks
Check the heat exchangers of the air-conditioning unit for dirt
particles each time a tube is replaced. Dirty heat exchangers
reduce the performance of the air-conditioning unit.
Open the bed (Section 5.8) and vacuum-clean the heat
exchangers, if necessary.
Step
Procedure
Reference
1
To close the bed, push it down.
2
Turn the key in the middle of the lower front cover
clockwise as far as possible. The bed is drawn to the
base part and is bolted fi rmly again.
Step
Procedure
Reference
1
Open the bed (see Section 5.8) and regularly check
the following items:
2
The air hose of the air-conditioning unit must not have
any kinks and must be able to blow the air off freely.
3
The fi lter mats must be clean.
4
The maximum hose length of 6 m must not be
exceeded, unless there is an additional ventilator.
5
An adequate ventilation and air extraction in the studio
must always be guaranteed.