O p e r a t i n g I n s t r u c t i o n s
|
megaSun 7000/7800 alpha
42
ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior control panel.
No.
Status message
Description
Remedy
26
Frequency detection: power
supply connection faulty
(connector X6/E6)!
Frequency detection failed. No mains
voltage.
Check mainboard connector X6/E6.
INFORMATION MESSAGES
No.
Info. message
Description
Remedy
203
Fill level aquaCool canister
low
The content of the aquaCool canister is
sufficient for another 2.5 hours of operation
with a spraying time of 6 seconds each.
Replace the empty aquaCool canister with a full one.
Do not replace aquaCool with any other liquid.
204
Connection aquaCool unit
faulty
Communication between control and
module/interior control panel has been
interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your Customer Service.
205
Connection audio module
faulty
206
Connection inside display
faulty
207
aquaCool canister empty
aquaCool canister empty.
Replace the aquaCool canister with a full one.
See chapter: Refilling Aroma and aquacool
208
Aroma supply low, please
renew
System has run out of scent.
Replace the Aroma tin.
See chapter: Refilling Aroma and aquacool
209
aircon: condensed-water
canister full, please empty
Condensate canister of air-conditioning
unit full.
Empty the condensate canister of the air-conditioning
unit, acknowledge the message by pressing START.
210
Low battery charge, please
renew
Button cell (CR-2032) of the control board
discharged.
Replace the button cell (CR-2032).
211
Connection preselect display
faulty
Communication between control and
“preSelection” control panel has been
interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your Customer Service.
212
Connection RGB-module
faulty
213
SD card missing
No SD card in the audio module.
Insert an original SD card. See chapter: Recording to
an SD card/Removing the SD card
214
SD card unreadable
SD card defective, incompatible content.
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter: Recording
to an SD card/Removing the SD card. If the fault
persists, contact your Customer Service.
215
Connection to easy Care ter-
minal faulty
Communication between control and
easyCare terminal has been interrupted.
Check cable connections and power supply.
Acknowledge the message by pressing START. If the
fault persists, contact your Customer Service.
216
Voltage varies, please check
Power supply to the mainboard varies
Check power supply to the mainboard.
217
No voice files on the SD
card, pleas check.
No voice files on the SD card found.
Rebuild voice folder on the SD card. If necessary
replace original SD card.
218
Connection DALI-unit faulty.
DALI-unit - CAN-BUS connection lost.
Contact your customer service.
219
Connection rubinColl unit
faulty.
Driver collagen booster. CAN-BUS con-
nection lost.
Contact your customer service.
226
Quicktest Sensortolerance
OK
Sensor Quicktest log entry - No display
appears - Message will be stored directly
in the event log (service menu).
-
227
Quicktest Sensortolerance
error
230
Connection Bluetooth
module faulty
Communication between control and
bluetooth module has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your Customer Service.
231
No display
Internal notification - stored in the error log
(service technician information).
-
Содержание MegaSun 7000a
Страница 1: ...OPERATING INSTRUCTIONS PRODUCT LINE ...
Страница 2: ......
Страница 48: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 48 Remarks ...
Страница 49: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 49 Remarks ...
Страница 50: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 50 Remarks ...
Страница 51: ......