39
Cooling and exhaust air
COOLING PRINCIPLE
Cooling of the tanning unit
: The fan sucks in the
ambient air for cooling through the upper and lower
fi lter pads. It discharges the warm air via the exhaust
air duct.
Cooling of the body
: A fan at the foot end sucks
in ambient air (systems without air-conditioning unit)
or cooled air (systems with air-conditioning unit) and
blows it into the tanning space of the solarium. A
spoiler at the canopy pane leads this air to the face
area.
Cooling of the bed pane
: The air that is cooled down
in the air-conditioning unit is blown towards the foot
end between the bed pane and the ducting pane and
then led further into the tanning space.
MAINTENANCE OF THE EXHAUST AND AIR-
CONDITIONING UNIT
A clean and trouble-free exhaust-air unit prevents
the tanning system from overheating. The maximum
exhaust-air hose length of 6 m must not be exceeded
unless there is an auxiliary fan installed.
Procedure
Fig.
1
Check the air-conditioning unit and the
condensate pump as described in the
following chapter.
39.1
2
The fi lter pads in the bed section and
in the canopy must be clean.
37.4
37.5
3
Check the exhaust-air hose for kinks
and damages; also test the function of
the auxiliary fan in the case of excessive
hose lengths.
4
Suffi
cient airing and ventilation of
the tanning studio must always be
ensured.
5
Check the correct positioning of the
ducting pane in order to ensure the
proper cooling of the bed pane.
Air-conditioning unit and
condensate pump
MAINTENANCE OF THE AIR-CONDITIONING
UNIT
Check the heat exchangers of the air-conditioning
unit for dirt accumulation with each tube replacement.
Soiled heat exchangers reduce the performance of
the air-conditioner.
•
Open the front cover and vacuum-clean the heat
exchangers, if necessary.
•
Check the air hose each time you change tubes. If
it is defective, replace it immediately.
Figure 39.1: Air-conditioning unit and condensate pump
⑯
⑬
⑭
⑮
13
Condensate hose
14
Condensate pump
15
Condensate tray
16
Position of air hose and fan