M a n u a l e o p e r a t i v o
|
megaSun 4000 / 4500
36
•
After having removed the screw, you can take off
the interior cover. There is a coloured Plexiglas pane
under the cover; this pane can also be removed.
Figure 36.1
•
Then you can access the tube and replace it. Make
sure to replace the starter (
fi gure 36.1, zoomed)
with
each tube replacement.
•
Installation is carried out in reverse order.
DECORATIVE TUBES IN THE CANOPY (MS 4500)
•
The chromium facings of the “eyes” are only fi xed with
Velcro tape. They can easily be removed by hand.
Figure 36.3
Figure 36.2
•
Undo the four screws fi xing the carrier plate and lift
off the plate.
•
Pull the defective lamp carefully out of its fi xture.
(Do not turn it!).
Figure 36.4
Figure 36.5
•
When inserting the new compact fl uorescent lamp,
make sure that the lamp is correctly connected to
the fi xture (see
circle
).
•
Fasten the carrier plate and ensure that the edge
of the diffusing panel
(fi gure 36.6)
is positioned below
the carrier plate.
Figure 36.6
Dif
fusing panel
•
At last, fi x the chromium-plated facing.