Thrulink Operations Manual 

 

TROUBLE-SHOOTING 

 

Problem 

Suggestion 

Cannot access web 
GUI 

- Verify correct static IP settings for your computer.  
- Verify secure web browser address is used 
(

https://192.168.1.10

 for example) 

- Attempt to ping the device and check for network connectivity. 
- If ping replies, reboot/power cycle the ThruLink 
- Connect to WAN port and ping WAN IP. If ping replies, access 
the GUI using the WAN IP using the https protocol. If LAN and 
WAN configurations are set to the same subnet, change to 
differing subnets. 
- If still unresponsive, escalate for support 

 
Problem 

Suggestion 

Cannot log in to 
web GUI using 
ID/Password 

- Verify correct ID and password 
- If system has been defaulted, access using default “admin / 
admin” 
- Connect to serial console, choose option 2 to reset interface 
password “admin” 

 
Problem 

Suggestion 

Unsure the network 
is working correctly 

- Use the network tool to ping the gateway IP 
- Use the ping tool to verify other devices on the network 
respond 
- If no response, verify ISP/WAN/LAN configurations 
- Check Tunnel Mode activity messages from System page (see 
page 13 of this manual for details). 
- Power cycle router 

 
Problem 

Suggestion 

Tunnel will not 
connect 

- Check Tunnel Mode activity messages from System page (see 
page 13 of this manual for details).  
- Ping remote Server/Client WAN IP using Network ping tool 
- Ping remote Server/Client WAN IP using MS Command Prompt 
- If applicable, ping gateway IP using local ThruLink Network ping 
tool 
- If applicable, ping gateway IP using MS Command Prompt 
- Verify Firewall settings. If firewall enabled, verify ICMP port has 
been allowed. Disable firewall to check if connection can be 
established. If the MS firewall is disabled, verify no other firewall 
software is enabled. 
- Verify router ports are correctly forwarded 

 

Further assistance is available by contacting the nearest KBC technical support 

representative. See preface page “ii” for contact information and availability. 

 
 
 
 
 
25 

 

Thrulink Operations Manual 

 

WARRANTY INFORMATION 

 
KBC extends the following LIMITED WARRANTY to the original owner/purchaser of this 
product as follows: 

-

 

Two years from the date of initial sale for all wireless and network products. 

-

 

Five years from the date of initial sale for all fiber products. 

1)

 

If, within the specified warranty period, this product, or any part or portion thereof, 
shall prove upon examination by KBC, to be defective in material or workmanship, 
KBC will repair or replace such part or portion at KBC’s option.  The warranty 
period on the repaired or replaced part or portion of this product shall be limited to 
the unexpired term of the original warranty.  The buyer shall be responsible for all 
shipping and transportation of the product to KBC for any performance under this 
warranty. 

2)

 

Conditions and Exceptions: 
a)

 

Any accident to this product, any misuse or abuse, alternation, use in modified 
form, or any attempt to repair this product shall void this warranty.  These 
conditions to the warranty include, but are not limited to, incorrect power 
connections, physical damage due to mechanical shock, exposure to moisture, 
and circuit modification. 

b)

 

SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE, THE 
BUYER, NOT THE MANUFACTURER, DISTRIBUTOR, OR RETAILER, ASSUMES 
THE ENTIRE COST OF ALL SERVICING OR REPAIR, EXCEPT AS OTHERWISE 
PROVIDED BY THE TERMS OF THIS WARRANTY. 

c)

 

FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT, 
THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES. (1) THE COST OF 
LABOR TO REPAIR OR REPLACE DEFECTIVE PARTS OR PORTIONS OF THIS 
PRODUCT, AND (2) THE COST OF THE REPAIRED OR REPLACE PARTS OR 
PORTIONS OF THIS PRODUCT. 

d)

 

NO OTHER EXPRESSED OR IMPLIED WARRANTIES HAVE BEEN MADE OR WILL 
BE MADE ON BEHALF OF KBC WITH RESPECT TO THE SALE, REPAIR, 
INSTALLATION, OPERATION, OR REPLACEMENT OF THIS PRODUCT.  KBC 
DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THIS 
PRODUCT OR ITS FITNESS FOR ANY PURPOSE, AND THE BUYER AGREES THAT 
THIS PRODUCT IS SOLD “AS IS” AND THAT THE ENTIRE RISK OF QUALITY 
AND PERFORMANCE OF THIS PRODUCT IS WITH THE BUYER, EXCEPT AS 
OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY. 

e)

 

Some states/jurisdictions do not allow exclusions or limitations of incidental or 
consequential damages, or limitations on how long an implied warranty lasts, 
so the above exclusions or limitations may not apply to you. 

f)

 

If you do not wish to be bound by any of the provisions in this 

warranty, please return the product(s) immediately. 
3)

 

Contact your dealer regarding return authorizations for out of 

warranty repairs and     any further product information. 

 
 

 

 

 

 

 

 

 

26 

Содержание ThruLink THLK Series

Страница 1: ... A Main 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com ThruLink LAN WAN Transmission Systems Operations Manual Version 20110519 ...

Страница 2: ...hnical assistance is available should you require additional assistance KBC offers technical support over the phone or by way of e mail to all KBC qualified integrators on the ThruLink product The North American technical support hotline is available during regular US west coast business hours Monday through Friday on all non major holiday business days KBC will follow up on all electronic inquiri...

Страница 3: ...IGH CAPACITY ENVIRONMENTAL CONDITIONING The High Capacity ThruLink is an industrial server and must be stored in a conditioned environment Maintain temperature ratings in the server room within the temperature threshold as stated on the device specifications and ratings Rack Mount Instructions The following or similar rack mount instructions are included with the installation instructions A Elevat...

Страница 4: ...f cable is usually determined by the laptop Ethernet port If using a 10 100 port a crossover cable may be required If using a gigabit port the straight through cable should connect to the ThruLink 3 Connect the supplied 12 VDC 1000mA power supply to the DC jack as labeled on the Standard Capacity SC Connect the power supply to a sufficient voltage suppression device 4 Configure the static setting ...

Страница 5: ...pair can be sent directly to KBC with a valid RA number RA s are issued to KBC distributors dealers or integrators with a valid resale license End users should return products through their KBC dealer who can call or e mail KBC to obtain an RA number for repair 3 Thrulink Operations Manual THRULINK PHYSICAL DETAILS STANDARD CAPACITY STANDARD CAPACITY SINGLE DUAL LAN PORT THLK S2 Wx THLK S3 Wx A RE...

Страница 6: ...t both types of cables are on hand in case your particular device requires a different configuration than what KBC has tested 6 A REAR VIEW 1 Fan 2 Power Input Port 3 Serial Connection 4 WAN port 5 LAN port B FRONT VIEW 6 LCD Display 7 Power Off Hold for two seconds 8 Power On Hold for two seconds 12 VDC PS Ethernet Cat5 or 6 cable connect to network Ethernet Cat5 or 6 cable To PC serial port for ...

Страница 7: ...INK TUNNEL Out of the box the ThruLink units are set to default Tunnel Mode Disabled In order to connect two or more units together one unit must be enabled as SERVER and the other s to which the Server will connect must be configured as CLIENT S Each Client must have its respective Server WAN IP entered into the Primary Server IP section The WAN Configuration above shows the IP and netmask chosen...

Страница 8: ...able IP on the same subnet as the Server other than the Server LAN IP 17 Click SAVE and then reboot device Visit www thrulink net TLV2 to view a brief web tutorial for 2 minute KBC ThruLink tunnel set up procedure 9 Thrulink Operations Manual ADVANCED OPERATION WEB BROWSER INTERFACE Each ThruLink has a web browser interface to access the advanced setup functions If changing advanced settings be su...

Страница 9: ...ommand tool to be used along with the Command Prompt to ping trace the LAN or WAN IP addresses of other ThruLink or Ethernet devices on the network 11 Thrulink Operations Manual ADVANCED OPERATION CONTINUED Network Diagnostics Continued SNMP Enable Default configuration is SNMPv3 Disabled To enable simply click the Blue Disabled button in order to see the Enabled option 3 System The opening page o...

Страница 10: ...hing link STATUS ACTIVE Upon a link to Server WAN IP STATUS LINK LOST If the Client loses the link it will reattempt the connection STATUS INCORRECT SERVER WAN IP STATUS UNABLE CONTACT If the Server WAN IP is correct check the port selected to ensure ports are forwarded STATUS PSK MISMATCH 13 Thrulink Operations Manual ADVANCED OPERATION CONTINUED c WAN Interface Media Type IEEE 802 11 Wireless Et...

Страница 11: ...llow access through only the LAN or only the WAN port s ii Tunnel Mode Options The ThruLink is set to Disabled Tunnel mode out of the box The user must select the intended mode for each ThruLink device KBC recommends setting the Server first as the Client must have the Server WAN IP information entered into it to connect the tunnel The various options are shown below 1 Server Mode Below are the op...

Страница 12: ... In the picture below the Client is set to communicate to its primary Server whose WAN IP address is 10 0 0 10 on Port 8080 The Host Name does not need to match the Server Host Name in order to establish the tunnel A secondary Server if one is available can be used as the Failover Server in the event the connection is lost to the primary Server A failover Server will only receive the information f...

Страница 13: ...ng Below are the options to select the DNS settings 2 Example of settings The following are example configurations insert your settings from your ISP 19 Thrulink Operations Manual ADVANCED OPERATION CONTINUED a LAN Configuration Select a LAN IP and Subnet mask See page 9 if the LAN configuration will match the existing network settings If a different subnet will be used select the desired configur...

Страница 14: ...GUI interface cannot be reached via the LAN or WAN ports set up can be performed through the serial connection The console is designed to change only the minimum required information to enable access to the system via a network Once network access has been established the web GUI provides complete system configuration as detailed in pages 8 through 21 To use the serial console of the system a null...

Страница 15: ... plug type determined by part number APPROVALS FCC ID IC CE Warranty 2 YEAR LIMITED WARRANTY SEE PAGE 25 FOR DETAILS 23 Thrulink Operations Manual THRULINK PRODUCT SPECIFICATIONS CONTINUED For product improvement design and specifications are subject to change without notice HIGH CAPACITY THLK H2 Rx Series Bandwidth 650 Mbps unencrypted 400 Mbps encrypted 128 bit NETWORK MANAGEMENT User Interface ...

Страница 16: ... years from the date of initial sale for all fiber products 1 If within the specified warranty period this product or any part or portion thereof shall prove upon examination by KBC to be defective in material or workmanship KBC will repair or replace such part or portion at KBC s option The warranty period on the repaired or replaced part or portion of this product shall be limited to the unexpir...

Отзывы: