background image

 

eCopper™

 

 

 

 

 

QSG-EERF8-GN3-R-RX-B_Series-Rev2101 

www.kbcnetworks.com 

Copyright © KBC Networks 2021 

Quick Start Guide 

EERF8-GN3-R-RX-B 

EoU Receiver 8*UTP Ports and 3*1000M RJ45 

 

Introduction  

The KBC EERF8-GN3-R-RX-B series is an Ethernet over UTP (EoU) receiver with 
8 UTP ports supplying Power over Wire (PoW) and 3*10/100/1000M Ethernet 
ports. This receiver provides connectivity up to 8 PoW/PoE (EERF1-LS1-T-MN-
B) transmitters. Power is supplied to the transmitter through the UTP cable. 
Varying data rates are supported depending on cable distance and quality. 
This product also provides PoW management which allows the operator to 
remotely switch power on or off to any of the UTP channels. Plug-and-play 
design ensures ease of installation with no electrical adjustment needed. LED 
indicators are provided to show the operational status of the unit. 

This receiver is available in 1U rack configuration. 

Features 

 

8 UTP ports with PoW 

 

3 *10/100/1000M Ethernet ports (1 on the front and 2 at the rear) 

 

PoW management  

 

Full switching capability 

 

Connects up to 8 (EERF1-LS1-T-MN-B) transmitters  

 

UTP data rate >40Mbps (300m) 

 

Based on cable quality, cable pairs used (1,2, or 4 pairs) and voltage 
applied to cable (48~57VDC) from headend, PoE and PoE+ are supported 
by PoW up to 400m 

 

Over current and short circuit protection 

 

Unique PoW transmission protection design so that no power is output 
when the transmitter end is not connected. 
 

Downloads 

Full specifications, features and additional information can be found on the 
KBC website: 

www.kbcnetworks.com

. 

 

 

Содержание eCopper EERF8-GN3-R-RX-B

Страница 1: ...of the UTP channels Plug and play design ensures ease of installation with no electrical adjustment needed LED indicators are provided to show the operational status of the unit This receiver is available in 1U rack configuration Features 8 UTP ports with PoW 3 10 100 1000M Ethernet ports 1 on the front and 2 at the rear PoW management Full switching capability Connects up to 8 EERF1 LS1 T MN B tr...

Страница 2: ...visible damage which may have been caused during shipping Physical Deployment This equipment must be installed and operated in accordance with instructions found in this document Failure to comply with these instructions will invalidate the warranty Application ...

Страница 3: ...anel NOTICE DISCONNECT THE AC POWER CABLE BEFORE SERVICING 10 100 1000Base T 1 2 3 4 5 6 7 8 1 2 Reset Rear Panel LED Color Status Description PWR Green On The power supply is normal IP LINK Green On 3 10 100 1000M Network link is normal U LINK Green On EoU connection is normal I MAX Green On When the total power of 4 channels more than 175W PoW1 8 Green On PoW power on ...

Страница 4: ...oW 3 PoW 4 PoW 5 PoW 6 PoW 7 PoW 8 PoW Notes Please use straight through cable rather than cross over cable 8 wires transmission all 8 wires need to be connected 4 wires transmission any 2 wires of PIN 1 2 4 and 5 as any 2 wires of PIN 3 6 7 and 8 as 2 wires transmission any 1 wire of PIN 1 2 4 and 5 as any 1 wire of PIN 3 6 7 and 8 as ...

Страница 5: ...Page 5 of 8 Dimensions Unit mm C L IN K IP L IN K I M A X P o C PWR 1 4 5 8 9 12 13 16 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 1 2 3 3 10 100 1000Base T 1 4 5 8 9 12 13 16 ...

Страница 6: ...ion time 2mS Transmission distance 400m Ethernet Port RJ45 10 100 1000M SFP optional 1G Transmission medium Cat5e 6 Standard IEEE802 3 IEEE802 3U Ethernet delay 1mS Protection ESD IEC61000 4 2 Anti thunder protection IEC61000 4 5 level 3 Operation Environment Operating temperature 20 70 Storage temperature 40 85 Humidity No Condensing 0 90 Mechanical Dimension L W H 280mm 440mm 44mm Material Alumi...

Страница 7: ...ect to the grounding terminal 5 Check that the installation is correct and power on the device to be sure it is operating normally Troubleshooting Please refer to the following information if the device does not work Confirm the installation is according to the factory installation requirements Confirm the RJ45 cable order is following the EIA TIA568A or 568B industry standards The maximum transmi...

Страница 8: ...Page 8 of 8 Need Help Please visit our website www kbcnetworks com or contact your nearest KBC office or dealer ...

Отзывы: