7
Control Set for 230 VAC
(Factory Setting)
Control Set for 115 VAC
TABLE 3 – SETTING AC LINE VOLTAGE
WITH JUMPER J2A and J2B
FIG. 5 – MOTOR OUTPUT TORQUE vs POTENTIOMETER ROTATION – [TORQUE MODE]
FIG. 6 – MOTOR SPEED vs APPLIED MOTOR LOAD – [TORQUE MODE]
B. J2A, J2B – Input AC Line Voltage –
Select proper input line voltage
115VAC or 230VAC by placing
both
J2A and J2B in the correct
corresponding positions, "115V" or
“230V.”
C. J3 – Armature Voltage Output and
Tach-generator Feedback –
Select
the desired armature voltage by
placing J3 in the proper position “90V”
for 90 – 130VDC motors and
“180V"
for 180 – 220 VDC motors. For
115VAC line input the armature voltage must be set to “90V.”
Содержание KBPC-240D
Страница 6: ...3 FIG 1 CONTROL LAYOUT Illustrates Factory Setting of Jumpers and Approximate Trimpot Settings...
Страница 7: ...4 INCHES mm FIG 2 MECHANICAL SPECIFICATIONS TM TM...
Страница 20: ...20 FIG 17 CONNECTION DIAGRAMS FOR KBPC 240D WITH KBSI 240D SIGNAL ISOLATOR...
Страница 36: ...NOTES 12...
Страница 37: ...NOTES 13...