O P E R A T I N G   I NS T R U C T I O N S

 

 

During this condition air conditioner will stop heating operation and start defrosting automatically. The 
time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of 
frost buildup on the outdoor unit.

 

 

2. 

A white mist coming out from the indoor unit

 

A white  mist  may  generate due  to  a  large  temperature  difference between air  inlet  and  air  outlet  on 

COOL mode in an indoor environment that has a high relative humidity.

 

A white mist may generate due to moisture generated from defrosting process  when the  air conditioner 

restarts in HEAT mode operation after defrosting.

 

 

3. 

Low noise of the air conditioner

 

You may hear a low hissing sound when the compressor is running or has just  stopped running. This 

sound is the sound of the refrigerant flowing or coming to  a stop.

 

You can also hear a low "squeak" sound when the compressor is running or has just stopped running. 

This  is  caused  by  heat  expansion and  cold  contraction of  the  plastic  parts  in  the  unit  when  the 
temperature is changing.

 

A noise may be heard due to louver restoring to its original position when power is first turned on.

 

 

4. 

Dust is blown out from the indoor unit.

 

This is a normal condition when the air conditioner has not been used for a long time or during first use of 

the unit.

 

 

5. 

A peculiar smell comes out from the indoor unit.

 

This is caused by the indoor unit giving off smells permeated from building material, from furniture,  or 

smoke.

 

 

6. 

The air conditioner turns to Fan Mode from COOL or HEAT (For cooling and heating 

models only) Mode.

 

When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop 

automatically, and the air conditioner turns to Health mode. The compressor will start again when the 
indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models 
only) to the set point. 

 

7.  Dripping  water  may  generate  on  the  surface  of  the  indoor  unit  when  cooling  in  a  high  relatively 

humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet 
position and select HIGH fan speed. 

 

8. 

Heating mode (For cooling and heating models only)

 

The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating 

operation. When  the  outdoor  temperature  drops,  the  heat  drawn  by  the  air  conditioner  decreases 
accordingly.  At  the  same  time,  heat  load  of  the  air  conditioner  increases  due  to  larger  difference 
between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air 
conditioner, we suggest you use a supplementary heating device. 

 

9. 

Auto-restart function

 

Power failure during operation will stop the unit completely. 
For  the  unit  without  Auto-restart  feature,  when  the  power  restores,  the  OPERATION  indicator  on  the 

indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. 
For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all 
the previous settings preserved by the memory function. 

 

10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. 
Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button 

on the remote controller to restart operation. 

 

11. 

Vent function

 

This machine is special designed with Vent function; it is automatically initiated by the fan motor. The air 

conditioner have a vent pipe in the indoor unit, when the fan motor is operational, the indoor polluted 
air flow out of the room via the vent pipe. 

Содержание KPV-140

Страница 1: ...Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference This manual only describes the outdoor unit of user s When using the indoor unit refer to the user s manual of indoor unit ...

Страница 2: ......

Страница 3: ...d in accordance with the national wiring standards by authorized personnel only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not ...

Страница 4: ...ty has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wil...

Страница 5: ...fied power cord It may cause electric shock or fire Do not direct airflow at room occupants only This could damage your health Always ensure effective earthing Do not allow water to run into electric parts Always install circuit breaker and a dedicated power circuit No earthing may cause electric shock Disconnect the power if strange sounds smell or smoke comes from it It may cause fire and electr...

Страница 6: ...pliance or accident Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Turn off the main power switch when not using the unit for a long time It may cause failure of product or fire Do not use strong detergent such as wax or thinner Use a soft cloth for cleaning Appearance may be d...

Страница 7: ...arp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and circuit breaker are turned off Service For repair and maintenance contact your authorized service dealer Operating temperature Mode Temperature Cooling operation Heating operation Drying op...

Страница 8: ... pipe 8 Connection cable 9 Connection pipe 10 Refrigerant pipe port 11 Air outlet 1 3 4 2 11 5 10 6 9 8 7 NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE This manual does not include Remote Controller Operations see the Remote Controller Instruction packed...

Страница 9: ...9 ...

Страница 10: ...f the arrow AUTO COOL DRY HEAT for cooling heating models only FAN ONLY Mode indicators illuminate under the different mode settings Auto Automatically choose the operation mode by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller The fan speed is automatically controlled Cool Enables you to enjoy the cooling effect at you preferred...

Страница 11: ...kly from zone to zone 2 For the models adopt DC motor Select LOW fan speed and the first zone will illuminate Select MED fan speed and the second zone will illuminate Select HIGH fan speed and the third zone will illuminate Select AUTO fan speed and zones 1 3 will illuminate Note when the indoor fan is stopped nothing will display 4 buttons 1 Temperature adjustment Press and to adjust the temperat...

Страница 12: ...oling mode the fan motor will operate at super high fan speed and the set temperature will reach in the shortest time After half an hour the fan speed will revert to the previous set fan speed The fan speed can be adjusted under Turbo operation When select this function in heating mode for the unit without PTC heater the Turbo indicator lights up without fast heating operation This function is ava...

Страница 13: ...le And the LOCK indicator illuminates Push it again to cancel the LOCK mode WARNING Manually moving the horizontal and vertical airflow direction louvers could damage the air conditioning unit Note The starting angle of the horizontal louver should not be too small otherwise the narrow air outlet will affect cooling or heating efficiency Do not set the starting angle of the louvers too small durin...

Страница 14: ... the air conditioner turns to Health mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point 7 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidity higher than 80 Adjust the horizontal louver to the maximum air outlet position ...

Страница 15: ...15 ...

Страница 16: ...ed the performance will decrease and electricity will be wasted The air filter should be checked and cleaned about once every 2 weeks to maintain optimal performance of the air conditioner The back view of the air inlet grid Air Filter Right side filter Knob both sides Left side filter Air inlet grid It is tied by a rope inside Bottom filter NOTE The Anti for mol filter fixed on the Air filter doe...

Страница 17: ...or half a day 3 Turn off the unit and switch off the power switch remove the batteries from the remote control 4 Periodically check and clean the inner parts of the outdoor unit Our local dealer will help you handle this if you contact us After long time idleness Before restarting please check if the air inlet and air outlet of the indoor and outdoor units are blocked up Clean it so After sales If...

Страница 18: ...ioner does not cool or heat well The temperature setting is too high or too low Set a more comfortable temperature The air filter is clogged with dust Clean the filter The air inlet or outlet of the outdoor unit is blocked Clear up the block Doors or windows are open Close the doors or windows Air conditioner does not cool or heat at all The air inlet or outlet of the outdoor unit is blocked Clear...

Страница 19: ...perature is warm enough the function stops automatically 8 P8 Current overload protection Contact service people 9 Ed Outdoor protection Turn off the unit clean the air filter and then restart the unit If this operation does not work please contact service people The displayed error code differs from appliance to appliance The actual display of the indoor unit shall prevail Show on the LCD of the ...

Страница 20: ......

Отзывы: