SAFETY  PRECAUTIONS

 

 

 

 
 
 
 
 
 

 
 
 

CAUTION

 

 

 

When  the  air  filter  is  to  be 
removed,  do  not  touch  the 

metal parts of the unit. 

 

It may cause an injury.

 

Do not clean the air 
conditioner with water.

 

 
 

Water  may  enter  the  unit  and 
degrade  the  insulation.  It  may 
cause an electric shock. 

!    

Ventilate the room well 
when used together 
with a stove, etc. 

 

An oxygen shortage 
may occur. 

 

 

When the unit is to be 
cleaned, switch off, and turn 
off the circuit breaker. 

 

Do not clean unit when power 
is on as it may cause fire and 
electric shock, it may cause 
an injury. 

 

Stop operation and close 
the window in storm or 
hurricane.

 

 

Operation with windows 
opened may cause wetting 
of indoor and soaking of 
household furniture.

 

Do not put a pet or house 
plant where it will be 
exposed to direct air flow. 

 

This could injure the pet or 
plant.

 

 

 
 

 

Do not place obstacles 
around air-inlets or inside 
of air-outlet.

 

 

It may cause failure of 
appliance or accident.

 

Do not use for 
special purposes. 

 
 

Do  not  use  this  air 

conditioner  to  preserve 

precision  devices,  food, 

pets,  plants,  and  art 

objects.

 

It may cause deterioration of 

quality, etc.

 

Turn off the main power 
switch when not using 
the unit for a long time.

 

 

It may cause failure of 

product or fire.

 

 

Do not use strong detergent 
such as wax or thinner. Use 
a soft cloth for cleaning.

 

 

Appearance may be 
deteriorated due to change 
of product color or 
scratching of its surface.

 

 

 

Do not place heavy object on the 
power cord and take care so that 
the cord is not compressed.

 

 

There is danger of fire or 
electric shock.

 

Ensure  that  the  installation  bracket  of 
the outdoor appliance is not damaged 
due to prolonged exposure.

 

 

If  bracket  is  damaged,  there 
is concern of damage due to 
falling of unit.

 

 

 

Use caution when unpacking 
and installing. Sharp edges 
could cause injury.

 

Always insert the filters 
securely. Clean filter 
once every two weeks.

 

 

Operation without filters 

may cause failure.

 

 

 
 

 

If water enters the 

unit, turn the unit off 

and disconnect the 

power, contact a 

qualified service 

technician.

 

Содержание KPV-140

Страница 1: ...Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference This manual only describes the outdoor unit of user s When using the indoor unit refer to the user s manual of indoor unit ...

Страница 2: ......

Страница 3: ...d in accordance with the national wiring standards by authorized personnel only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not ...

Страница 4: ...ty has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wil...

Страница 5: ...fied power cord It may cause electric shock or fire Do not direct airflow at room occupants only This could damage your health Always ensure effective earthing Do not allow water to run into electric parts Always install circuit breaker and a dedicated power circuit No earthing may cause electric shock Disconnect the power if strange sounds smell or smoke comes from it It may cause fire and electr...

Страница 6: ...pliance or accident Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Turn off the main power switch when not using the unit for a long time It may cause failure of product or fire Do not use strong detergent such as wax or thinner Use a soft cloth for cleaning Appearance may be d...

Страница 7: ...arp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and circuit breaker are turned off Service For repair and maintenance contact your authorized service dealer Operating temperature Mode Temperature Cooling operation Heating operation Drying op...

Страница 8: ... pipe 8 Connection cable 9 Connection pipe 10 Refrigerant pipe port 11 Air outlet 1 3 4 2 11 5 10 6 9 8 7 NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE This manual does not include Remote Controller Operations see the Remote Controller Instruction packed...

Страница 9: ...9 ...

Страница 10: ...f the arrow AUTO COOL DRY HEAT for cooling heating models only FAN ONLY Mode indicators illuminate under the different mode settings Auto Automatically choose the operation mode by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller The fan speed is automatically controlled Cool Enables you to enjoy the cooling effect at you preferred...

Страница 11: ...kly from zone to zone 2 For the models adopt DC motor Select LOW fan speed and the first zone will illuminate Select MED fan speed and the second zone will illuminate Select HIGH fan speed and the third zone will illuminate Select AUTO fan speed and zones 1 3 will illuminate Note when the indoor fan is stopped nothing will display 4 buttons 1 Temperature adjustment Press and to adjust the temperat...

Страница 12: ...oling mode the fan motor will operate at super high fan speed and the set temperature will reach in the shortest time After half an hour the fan speed will revert to the previous set fan speed The fan speed can be adjusted under Turbo operation When select this function in heating mode for the unit without PTC heater the Turbo indicator lights up without fast heating operation This function is ava...

Страница 13: ...le And the LOCK indicator illuminates Push it again to cancel the LOCK mode WARNING Manually moving the horizontal and vertical airflow direction louvers could damage the air conditioning unit Note The starting angle of the horizontal louver should not be too small otherwise the narrow air outlet will affect cooling or heating efficiency Do not set the starting angle of the louvers too small durin...

Страница 14: ... the air conditioner turns to Health mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point 7 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidity higher than 80 Adjust the horizontal louver to the maximum air outlet position ...

Страница 15: ...15 ...

Страница 16: ...ed the performance will decrease and electricity will be wasted The air filter should be checked and cleaned about once every 2 weeks to maintain optimal performance of the air conditioner The back view of the air inlet grid Air Filter Right side filter Knob both sides Left side filter Air inlet grid It is tied by a rope inside Bottom filter NOTE The Anti for mol filter fixed on the Air filter doe...

Страница 17: ...or half a day 3 Turn off the unit and switch off the power switch remove the batteries from the remote control 4 Periodically check and clean the inner parts of the outdoor unit Our local dealer will help you handle this if you contact us After long time idleness Before restarting please check if the air inlet and air outlet of the indoor and outdoor units are blocked up Clean it so After sales If...

Страница 18: ...ioner does not cool or heat well The temperature setting is too high or too low Set a more comfortable temperature The air filter is clogged with dust Clean the filter The air inlet or outlet of the outdoor unit is blocked Clear up the block Doors or windows are open Close the doors or windows Air conditioner does not cool or heat at all The air inlet or outlet of the outdoor unit is blocked Clear...

Страница 19: ...perature is warm enough the function stops automatically 8 P8 Current overload protection Contact service people 9 Ed Outdoor protection Turn off the unit clean the air filter and then restart the unit If this operation does not work please contact service people The displayed error code differs from appliance to appliance The actual display of the indoor unit shall prevail Show on the LCD of the ...