9.3.1 Check the water circuit
9.3 Water piping
If there is no glycol (anti-freeze) in the system or there is a power supply failure or pump failure, drain the system (as
shown in the figure below).
If water is not removed from the system in freezing weather when unit is not used, the frozen water may damage the
water circle parts.
NOTE
The unit is equipped with a water inlet and water outlet for connection to a water circuit. This circuit must be provided by a
licensed technician and must comply with local laws and regulations.
The unit is only to be used in a closed water system. Application in an open water circuit can lead to excessive corrosion
of the water piping.