Instructions for use PROPHYflex 3 - 2018 - 1.000.4672, - 1.006.9926, - 1.006.9928
5 Operation | 5.6 Instructions for use for PROPHYflex Pulver, PROPHYpearls®, PROPHY Superpearls®, PROPHYflex Per‐
io Powder
14 / 26
PROPHYflex powder
PROPHYpearls
®
Superpearls
®
PROPHYflex Perio Powder
Application:
▪ Conservative and aes‐
thetic dentistry
▪ Cleaning of tooth surfa‐
ces
▪ Removal of stains and
plaque
▪ Orthodontics and pros‐
thetics (pre- and after-
treatment of
• surfaces for gluing)
•
Application:
▪ Conservative and aes‐
thetic dentistry
▪ Cleaning of tooth surfa‐
ces
▪ Removal of stains and
plaque
▪ Orthodontics and pros‐
thetics (pre- and after-
treatment of
• surfaces for gluing)
•
Application:
▪ Subgingival treatment
▪ Removal of periodontal
biofilm
▪ Preservation of dental
implants (including tita‐
nium polish)
▪ For follow-up treatment
after the initial use in
periodontal therapy
PROPHYflex powder
PROPHYpearls
®
Superpearls
®
PROPHYflex Perio Powder
from pink to white
working
from pink to white
working
any
direction of work
water-soluble
slightly water-soluble
water-soluble
PROPHYflex powder
CAUTION
Hazard from the use of PROPHYflex on the gingiva.
The gingiva may be damaged.
▶ Do not direct the powder jet toward the gingiva. Always work from pink to white.
The front part of the instrument can be rotated to reach the optimum working position
at all times.
The powder spray can be guided from the occlusal margin to the cervical margin of
the tooth without danger of injuring the dental alveolus and the ligaments. Discolouring
the biofilm of plaque, for example with erythrosine solution, is a very efficient, noticea‐
ble tool for limiting the blasting time to the required local amount as the red is re‐
moved. The jet should not directly contact the gingival margin, exposed tooth necks,
or the mucosa. The handpiece tip should be held approximately 3-5 mm from the sur‐
face of the tooth.
The inclination angle of the tip varies according to the position of the tooth and sur‐
face to be cleaned. For gentle treatment, the angle between the powder jet and the
axis of the tooth should be 60
o
to 90
o
. The jet should not directly impinge on the gingi‐
val margin, exposed tooth necks or the mucosa. Work from pink to white.
The abrasion can vary on devices in which the drive air can be adjusted with a foot
switch.