Operating Manual
Original Operating Manual
15
Failure of the safety devices (e.g. the pressure relief valve and the non-return
valve) and incorrect connection of the controls to the actuators can cause
malfunctioning of the attachment and damage to it.
After mounting and before initial operation, check the functions and the
identification of the attached equipment with the movement directions of the
operating elements (operating lever, joystick, etc.).
6.2
Significant modification
Significant modifications are, for example, those which affect the stability, performance, speed and
strength of components.
The EC Declaration of Conformity is invalidated by a significant modification of the attachment.
Modifications to the attachment may only be made with prior approval by the manufacturer.
6.3
Schedule for routine maintenance and lubricants
Lubricants approved and recommended by KAUP
Greases
Note
Lithium soap grease
NLGI Class 2
e.g. Avialith 2
Designation DIN51825:
K 2 K-30
Complex soap grease
NLGI Class 2
e.g. Turmogrease Gel M 5
Foundry quality
Teflon spray
e.g. Wieds or Rivolta
Only for plastic sections
The specified maintenance schedules can change as a result of the operating conditions
such as extreme cold, heat and dust or poor ground conditions and this must be taken
into account by the owner.
With other loads, such as fork arms with a length of over 2,400 mm or raised load
centres, amended/shorter maintenance intervals should be agreed by the user with the
manufacturer.